Alto-Shaam 10.18 User Manual
Page 9
ELECTRIC COMBITHERM
—
INSTALLATION MANUAL
#MN-28677
PG
. 7
®
C O M B I T HE R M
1 0 • 1 0
E S
S P E C I F I C A T I O N S
C A PA C I T Y
FULL-SIZE PANS:
20" x 12" x 2-1/2"
Ten (10)
GN 1/1:
530 x 325 x 65mm
Ten (10)
HALF-SIZE SHEET PANS:*
18" x 13" x 1"
Ten (10)
ON WIRE SHELVES ONLY
120 lb (54 kg)
MAXIMUM
VOLUME MAXIMUM
: 75
QUARTS
(95
LITERS
)
W E I G H T
NET
404 lb
(183 kg)
SHIP
528 lb
(239 kg)
CRATE
49"
X
47"
X
37"
EST
.
DIMENSIONS
: (1245 x 1194 x 940mm)
E L E C T R I C A L
VOLTAGE
PHASE
CYCLE
/
HZ
AWG
AMPS
kW
at 208
1*
50/60
2 Wire plus ground
67.0
13.9
at 240
AWG 3
77.0
18.4
at 208
3
50/60
3 Wire plus ground
38.5/ph
13.8
at 240
AWG 6
44.0/ph
18.3
at 380
3
50/60
4 Wire plus ground
21.5/ph
14.2
at 415
AWG 10
25.6/ph
18.4
at 440
3*
50/60
3 Wire plus ground
20.0/ph
15.4
at 480
AWG 8
22.0/ph
18.4
*
ELECTRICAL SERVICE CHARGE APPLIES
20
8-
24
0
20
8-
24
0
38
0-
41
5
44
0-
48
0
33-1/16" (840mm)
4-15/16"
(125mm)
4
1
-1
/2
"
(1
0
5
3
m
m
)
3
3
-1
5
/1
6
"
(8
6
1
m
m
)
7
-9
/1
6
"
(1
9
2
m
m
)
6
0
-9
/1
6
"
(1
5
3
8
m
m
)
Water Drain
(Back Side)
30" (761mm)
4-3/4" (120mm)
3-3/16" (80mm)
1
1
-7
/1
6
"
(2
9
0
m
m
)
1
4
-3
/1
6
"
(3
6
0
m
m
)
1
5
-7
/8
"
(4
0
3
m
m
)
2" (50mm)
46-7/8" (1190mm)
43-7/8" (1114mm)
31-3/8" (796mm)
34-1/16" (865mm)
17-15/16"
(456mm)
7-9/16"
(191mm)
Water Drain
6
-1
/4
"
(1
5
8
m
m
)
41-15/16" (1064mm)
S
te
a
m
V
e
n
t
(T
o
p
)
Decalcification
Port
Electrical Connection (Bottom)
Treated Water
Intake (Bottom)
Untreated Water
Intake (Bottom)
D I M E N S I O N S :
H x W x D
EXTERIOR
:
41-1/2" x 43-7/8" x 34-1/16" (1053mm x 1114mm x 865mm)
EXTERIOR
WITH
RETRACTABLE
DOOR
:
41-1/2" x 47-7/8" x 34-1/16" (1053mm x 1216mm x 865mm)
INTERIOR
:
27" x 23-1/2" x 21-1/16" (685mm x 597mm x 535mm)
*
ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY
I N S TA L L AT I O N R E Q U I R E M E N T S
Oven must be installed level.
Hood installation is required.
Water supply shut-off valve and back-flow
preventer.
C L E A R A N C E R E Q U I R E M E N T S
LEFT
: 6" (152mm)
PLUS SERVICE ACCESS
:
18" (457mm)
RECOMMENDED
20" (508mm)
F R O M H E AT P R O D U C I N G E Q U I P M E N T
RIGHT
: 4" (102mm)
TOP
: 20" (508mm)
FOR AIR MOVEMENT
BACK
: 4" (102mm)
BOTTOM
: 5-1/8" (130mm)
FOR LEGS
COUNTER
-
TOP INSTALLATIONS MUST MAINTAIN
4" (102mm)
MINIMUM
CLEARANCE FROM COUNTER SURFACE
.
WAT E R R E Q U I R E M E N T S
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE
(1)
TREATED WATER INLET
:
3/4" NPT*
ONE
(1)
UNTREATED WATER INLET
:
3/4" NPT*
LINE PRESSURE
:
30 to 90 psi
2.8 to 6.2 bar
WATER DRAIN: 1-1/2"
CONNECTION WITH AIR GAP
* Can manifold off of one 3/4" line.
WAT E R Q U A L I T Y M I N I M U M S TA N D A R D S
USING A WATER SUPPLY NOT MEETING ALTO-SHAAM'S
MINIMUM WATER QUALITY STANDARDS WILL VOID THIS
WARRANTY. It is the responsibility of the purchaser to ensure that
incoming water supply is compliant with the specifications listed
through adequate treatment measures. Installation of the
CombiGuard™ Water Filtration System is recommended, but this
system may not address all water quality issues present.
Contaminant
Inlet Water Requirements
(untreated water)
Free Chlorine
Less than 0.1 ppm (mg/L)
Hardness
Less than 3 gpg (52 ppm)
Chloride
Less than 30 ppm (mg/L)
pH
7.0 to 8.5
Alkalinity
Less than 50 ppm (mg/L)
Silica
Less than 12 ppm (mg/L)
Total Dissolved
Solids (tds)
Less than 60 ppm