beautypg.com

Trio Motion Technology MC4N-ECAT User Manual

Page 8

background image

DISPLAY

The IP address and subnet
mask of the MC4N is
shown on the LCD display
for a few seconds after
power-up. The factory
default IP address is
192.168.0.250. This can
be changed using the
IP_ADDRESS command
via the Motion Perfect v3
software tool.

See back page for set-
up details.

DISPLAY EXAMPLE

DESCRIPTION

DETAILS

SYS

Displayed on

controller start

901

Model code :

Displayed on

power up

P900 : 2 axes

P901 : 4 axes

P902 : 8 axes

P903 : 16 axes

P904 : 32 axes

192.168.0.250

IP Address :

Displayed on power up OR after ethernet

connection for 15 seconds

Enable status

Error codes

Ann : Error on Axis nn

Unn : Unit error on slot nn

Caa : Confi guration error on unit nn, ie:

too many axes

E04 : VR/TABLE corrupt entry

IP Address / Run / Error code (see

table below)
EtherCAT Communications active
EtherCAT detection (fl ashing)

EtherCAT detected (steady)

I/O channels On / OFF

Enable status LED

Power LED

Error