DISPLAY
The IP address and subnet
mask of the MC4N is
shown on the LCD display
for a few seconds after
power-up. The factory
default IP address is
192.168.0.250. This can
be changed using the
IP_ADDRESS command
via the Motion Perfect v3
software tool.
See back page for set-
up details.
DISPLAY EXAMPLE
DESCRIPTION
DETAILS
SYS
Displayed on
controller start
901
Model code :
Displayed on
power up
P900 : 2 axes
P901 : 4 axes
P902 : 8 axes
P903 : 16 axes
P904 : 32 axes
192.168.0.250
IP Address :
Displayed on power up OR after ethernet
connection for 15 seconds
Enable status
Error codes
Ann : Error on Axis nn
Unn : Unit error on slot nn
Caa : Confi guration error on unit nn, ie:
too many axes
E04 : VR/TABLE corrupt entry
IP Address / Run / Error code (see
table below)
EtherCAT Communications active
EtherCAT detection (fl ashing)
EtherCAT detected (steady)
I/O channels On / OFF
Enable status LED
Power LED
Error