Digital economy seven programmer, Model: trtd7 - white, Specifications – Timeguard TRTD7 User Manual
Page 7: Tariff table
6
Resetting:
The TRTD7 can be reset to factory defaults by pressing and holding + and
- simultaneously until the screen goes blank, and then shows all segments.
The time and date may need resetting.
Sleep Mode:
If power is removed for any reason, then the internal battery will preserve the
programming, and also the time / date. The screen will go blank ten seconds
after the power is turned off, to preserve the battery life. It can be woken up
by pressing the + or - button, or by reapplying mains power to the unit.
8. Specifications:
Manual Permissible loads:
13A, 230V, 50Hz, suitable for immersion
heaters up to 3kW.
Ingress protection:
IP30
Insulation:
Class 1
Battery reserve:
Two years.
Standards:
Compliant with:
BS EN 60730, 72-23-EEC, and 89-336-EEC
Size:
175 x 120 x 70mm.
Switch type:
Double pole rocker switch
Digital Economy Seven
Programmer
Model: TRTD7 - White
WINTER
SUMMER
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Economy 7
0
1.00am 5.00am
2.00am 6.00am
1
12.00am 6.00am
1.00am 7.00am
2
1.00am 6.00am
2.00am 7.00am
3
1.00am 7.00am
2.00am 8.00am
ECO 20:20
4
10.00pm 6.00am
11.00pm 7.00am
ECONOMY 10
5
1.00am 6.00am 7.30pm 9.30pm
1.00am 6.00am 7.30pm 9.30pm
6
2.00am 7.00am 2.00pm 4.00pm 7.00pm 9.00pm 2.00am 7.00am 2.00pm 4.00pm 7.00pm 9.00pm
7
12.00am 5.00am 1.00pm 3.00pm 8.00pm 10.00pm 12.00am 5.00am 1.00pm 3.00pm 8.00pm 10.00pm
8
4.30am 7.30am 2.00pm 4.00pm 9.00pm 11.00pm 4.30am 7.30am 2.00pm 4.00pm 9.00pm 11.00pm
9
12.00am 7.00am 9.00pm 12.00am
12.00am 7.00am 9.00pm 12.00am
9. Tariff Table: