Timeguard TRT049 User Manual
Wiring centre box, Operating & installation instructions, Cat. no. trt049
For a product brochure please contact:
Timeguard Ltd. Victory Park, 400 Edgware Road,
London NW2 6ND Tel: 020-8452-1112
or email [email protected]
A Group company
67-058-331
HELPLINE
020-8450-0515
or email [email protected]
For assistance with the product please contact:-
3 Year Guarantee
In the unlikely event of this product becoming
faulty due to defective material or manufacture
within 3 years of the date of purchase, please
return it to your supplier in the first year with proof
of purchase and it will be replaced free of charge.
For years 2 and 3 or any difficulty in the first year
telephone the helpline on
020 8450 0515.
5. Specifications
Current rating:
10 A
Voltage: 230V,
50Hz
Operating temperature range:
0ºC to 50ºC
Complies with:
BS EN 60730
Conforms to directives:
73-23-EEC, 89-336-EEC
Wiring Centre Box
Cat. No. TRT049
Operating & Installation Instructions
3 Port Motorised Valve System (Y-Plan)
3
E
2
2
16
1
14
C
15
12
E
N
N
LS
L
L
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
N
N
N
N
Room Thermostat
Models TR
T030
TR
T031/32
TR
T033
TR
T035
Neutral not
requir
ed on
TR
T033 and TR
T035
WIRING CENTRE TR
T049
Note: Links shown
should be made by
the installer
Cylinder Thermostat
Model TR
T044
Boiler
Pump
Optional Fr
ost Stat
Model TR
T031
Pr
ogrammer
Models: TR
T034
TR
T036
HW
OFF
HW
ON
CH
ON
CH
OFF
HWS
(NO)
HWC
(NC)
A/C Mains in
(5 Amp fuse)
E
E
E
E
L
N
N
E
E
11
8
11
12
E
10
9
4
6
7
N
N
E
13
L
N
N
E
E
N
L
1
2
3
4
N
L
SL
Motorised V
alve
Br
own (L)
Orange CH Call (C)
Gr
ey HW (NO)
Y
ellow/Gr
een
Blue (N)
TRT049_200x120_Instructions.indd 2
TRT049_200x120_Instructions.indd 2
15/6/09 14:35:11