Timeguard TRT044 User Manual
Timeguard Thermometers
5. Specifications
Current rating:
16 (4) A
Voltage:
230V, 50HZ
Switch type:
Single pole, double throw
(SPDT)
Operating
temperature range: 0°C to 55°C
Set temperature
range:
40°C to 80°C
Complies with:
BS EN 60730
Conforms to
directives:
Conforms to
latest directives
Always isolate the mains supply before
starting work.
Incoming cable should be 1.5mm sq.
Remove cover from unit by unscrewing cover
retaining screw, and easing off the temperature
adjusting knob.
Thread incoming wire though the cable gland.
Allow sufficient excess cable to wire up the
unit, but not too much to make it difficult to
close the cover on the unit.
Connect the conductors to the relevant
terminals, according to the wiring diagram.
Ensure that the brass washer grips the conductor.
Pull some of the excess cable back through the
gland and then tighten the gland to trap the
cable and give good strain relief.
Replace the cover and the adjustment knob.
Adjust the length of the spring wire, and use it
to strap the TRT044 to the hot water cylinder.
Restore mains to the unit after checking all
system wiring is complete.
Cylinder/Pipe
Thermostat
Cat. No. TRT044
Operating & Installation Instructions
2. Siting
The TRT044 is designed to be surface mounted
onto the domestic hot water cylinder. For
cylinders with an insulating foam covering, a
section of foam must be removed so the back
of the thermostat is in direct contact with the
metal body of the tank.
The TRT044 should be mounted between a
quarter and third of the way up from the base
of the tank in a position that gives good access
to the dial.
3. Installation
This product should be installed by a qualified
installer to current installation standards.
If in any doubt contact the Timeguard Helpline
020 8450 0515.
Contents
TRT044 cylinder thermostat
TRT044 instruction leaflet
Spring wire
Wire strap
4. Operation
Use adjuster dial to set desired temperature.
For vulnerable people it may be advisable to
reduce the setting to as low as 50ºC bearing in
mind the outlet water temperature will be
somewhat higher than this due to the
temperature stratification in the tank.
To clean use a clean dry cloth only. Do not use
any liquid cleaners.
C 1 2
TRT044
Cylinderstat
Fig. 2
Wiring Diagram
Terminals C and 2 make on temperature rise.
Terminals C and 1 make on temperature fall.
Note:
Check boiler
instructions
before
connecting.
For a product brochure please contact:
Timeguard Ltd. Victory Park, 400 Edgware Road,
London NW2 6ND Tel: 020 8452 1112
or email [email protected]
A Group company
67-058-330 (issue 2)
HELPLINE
020 8450 0515
or email [email protected]
For assistance with the product please contact:-
3 Year Guarantee
In the unlikely event of this product becoming
faulty due to defective material or manufacture
within 3 years of the date of purchase, please
return it to your supplier in the first year with proof
of purchase and it will be replaced free of charge.
For years 2 and 3 or any difficulty in the first year
telephone the helpline on
020 8450 0515.
Note: a proof of purchase is required
in all cases. For all eligible replacements (where agreed by
Timeguard Ltd) the customer is responsible for all shipping/
postage charges for sending replacements outside the UK.
All shipping costs are to be paid in advance before
a replacement is sent.
Document Outline
- XTIM1561_TRT044_135x90_Instructions_iss2
- XTIM1561_TRT044_135x90_Instructions_iss2b.pdf