Connection
Connect the mains supply cable to the terminal block
on the unit as follows (see connection
diagram):
NEUTRAL (Blue)
N
EARTH (Green/Yellow)
LIVE (Brown)
L
Connect the cable from the lighting load to the terminal
block on the unit as follows (see connection diagram):
NEUTRAL (Blue)
N
EARTH (Green/Yellow)
LIVE (Brown)
L1
Ensure that all connections are secure.
Ensure the terminal block is attached to its mounting
posts in the sensor body.
Un-hook the sensor unit from the wall plate and
re-attach to the wall plate box as follows:-
Ensure no wires are trapped.
Align the sensor centrally over the wiring box and
attach the top edge of the sensor to the wall plate. see
diagram I. There will be an audible click indicating that
the top clips are located into the wall plate.
Slowly rotate the sensor body downwards and and
ensure no wires are trapped, the lower edge of the
unit will locate into the wallplate.
Fully tighten the fixing screw. See diagram F.
Installation is complete.
Connection
Diagram
Sensor onto the wall plate by use of the clip
arrangement on the wall plate. See diagram H. This
allows you to use your hands to hold the screwdriver,
and install the incoming cables with ease.
Connect the incoming and outgoing cables as follows.
Isolation switch
Load
Mains
supply