Timeguard RTS114 User Manual
Page 7
6
24 Hour Ring
Red tappet for ON operation.
Blue tappet for OFF operation.
Fig 2 shows an ON period starting at 1200 and ending at 1500.
24 Hour Control
If last tappet past time marker was blue 24 hour control
should show
•
(OFF) and ■ (ON) if it was red.
7 Day Ring
Segments with screwdriver slots positioned radially cause a change on the 7 day control.
The 7 day contacts are in series with the 24 hour contacts controlling the timeswitch output,
so the 7 day contacts need to be closed ( ■ – ON) for the 24 hour contacts to be operational.
Finally ensure permanent override indicator is set to AUTO.
4.0 5 Year Guarantee
In the unlikely event of this product becoming faulty, due to defective material or manufacture,
within 5 years of the date of purchase, please return it to your supplier with proof of purchase
and it will be replaced free of charge.
Should you encounter any difficulty please contact our helpline on 020 8450 0515.
5.0 Additional Tappets
4 red and 4 blue tappets are supplied with the RTS unit. If further tappets are required they may
be obtained from Timeguard quoting the numbers 934 3 311 BLUE, 934 3 035 RED.
Please ring 020 8450 0515.
3.5 Programming Overview
7 day output
control (blue)
Time marker
Clockwise direction for 24
hour and 7 day rings
Sunday markers
(in red)
7 day ring
24 hour ring
Radial slot
Fig 6
Note: all other 7 day ring segments
are in the no change orientation
and are not shown for clarity
2 segments set to give
changes to 7 day control
at midday Thursday and
midnight Thursday. With
7 day control set at ■ (ON)
above no 24 hour operation
will occur between midday
and midnight each Thursday.
24 hour control
(red)
Red tappet
Blue tappet