beautypg.com

Cycle time programming – Timeguard TR 636 top2 User Manual

Page 13

background image

13

Cycle time programming

In addition to switch-on and switch-off times (switching time) and short time pulses (pulse) cycle

times (cycle) can also be programmed. The pulse length (+ pulse pause) is limited to 17 hrs,

59 min, 59 sec
• Cycle times refers to cyclically repetitive time functions such as fan controls, urinal rinses etc.

Example: Switch on water rinsing Monday from 8:00 to 20:30 hrs every 15 min for 20 sec
(8:00

00

–8:00

20

On; 8:15

00

–8:15

20

On; 8:30

00

–8:30

20

On etc.)

Cycle programming
– Start cycle: Monday 8:00 hrs
– Pulse length: 20 sec
– Pause length: 14 min 40 sec
– Cycle end: Monday 20:30:00 hrs

Observe the number of maximum electrical switching cycles when using the ‚cycle‘ function.

GB

This manual is related to the following products: