LED Status Indicator Center – CHARGER MODE
Feature
LED Color
Function
Auto Standby
N/A
Over load
N/A
Over Temp
N/A
Ready
GREEN
Illuminated during FLOAT charge
Charging
YELLOW
Illuminated during BOOST charge
Inverter
N/A
Shore/StationPower
Green
LED Status Indicator Center – INVERTER MODE
LED Color
Auto Standby
N/A
Over load
N/A
Over Temp
N/A
Ready
GREEN
Charging
YELLOW
Inverter
GREEN
Shore/Station Power
GREEN
NOTE: This LED configuration indicates that the charger feature is functioning normally
and does not need any further attention. If the RED “Fault Condition” LED illuminates,
consult the Troubleshooting section of this manual.
INVERTER MODE START-UP:
After following the above charger instructions, confirm the rocker switch
on the remote panel is in the Off position.
Turn off the AC main shore/station power breaker.
If using a split-bus installation (see Installation section of this manual) turn off
all branch circuits associated with the inverter.
If powering the entire panel with the TruePower Combi, turn off all branch circuits.
Switch the remote panel rocker switch to On.
Observe the following on the Status Indicator Center and the Remote Panel:
Remote Panel LED Indicators – CHARGER MODE
LED Color
Shore/Station Power/Charger
GREEN
Inverter
N/A
Fault Condition
N/A
VERIFY THE REMOTE PANEL LEDS ARE AS FOLLOWS:
Remote Panel LED Indicators – INVERTER MODE
LED Color
Shore/Station Power/Charger
N/A
Inverter
GREEN
Fault Condition
N/A
VERIFY THE REMOTE PANEL LED’S ARE AS FOLLOWS:
BEGIN ENERGIZING THE AC CIRCUITS CONNECTED TO THE INVERTER:
Confirm the LED configuration continues to match the above table.
Confirm operation of all GFCI outlets and/or breakers attached to inverter power.
For any other LED configuration see the Troubleshooting section of this manual.
OPERATIONAL NOTE: Your TruePower Combi has built in safety features that can cause
the unit to shut down if it senses out of parameter operations such as over-voltage and
high temperatures. See the troubleshooting section of this manual for more details in the
event this occurs.
INVERTER OPERATIONAL CONSIDERATIONS
The TruePower Combi can be used to power any number of AC appliances normally only
available to you while hooked to shore/station power or operating a generator. Appendix
A includes a load calculation sheet from ABYC E-11 AC & DC Electrical Systems on Board
Boats. Below are typical appliances and their load ratings: