beautypg.com

Components – Prochem Everest CARB User Manual

Page 15

background image

COMPONENTS

EVEREST 980086 02/18/03

3-6

14. SOLUTION TEMPERATURE CONTROL

VALVE

This valve enables additional heat exchangers
to contribute more heat to the system if
necessary. By rotating the lever to the right it
adds more heat, by rotating to the left it removes
heat.

15. OIL CUP

The oil cup allows lubricant spray to reach the
vacuum blower.

16. VACUUM INLETS

The vacuum inlets serve as connecting point for
vacuum hoses.

17. SOLUTION OUTLETS

The solution outlets are the connecting point for
the high pressure cleaning hoses. These
outlets are quick disconnects that allow hoses to
be plugged into the unit.

18. SOLUTION SCREEN

The solution screen is located on the front of the
machine. The function of this screen is to trap
foreign particles from exiting the machine and
plugging the orifices of the cleaning tools. This
screen is part of the machine maintenance
cleaning.

19. CHEMICAL CHECK VALVE

The chemical check valve allows chemicals to
enter the system and travel in a singular
direction to the wand. The chemical check
valve prevents chemicals from traveling up-
stream into the solution system of the unit.

20. HIGH PRESSURE SOLUTION OUTLET

The control valve sets the pressure of the
solution system. This spring loaded valve can
be adjusted up or down setting the pressure of
the unit by turning the valve clockwise. The
pressure is increased or reduced by turning the
valve counter clockwise.

21. HIGH PRESSURE REGULATOR

The regulating valve controls the amount of
pressure in the pressure washing circuit by
turning the handle clockwise, It has the effect of
increasing the pressure. Turning it clockwise
has the effect of lowering the pressure.

22. WASTE OUTLET

This valve allows the waste tank to be emptied.
Turning clockwise opens the valve.

NOTE: This valve must be open during
operation.

23. WASTE PUMPOUT

This auxiliary pump serves to empty the waste
collection tank automatically. A float located
inside the tank automatically turns off and on
when the solution level reaches certain points.

24. WARM WATER OUTLET

The warm water outlet allows the cleaning
technician to drain hot water from the water box
for mixing chemical.

Water from this valve is hot.

25. WATER INLET

This quick connect allows the water supply hose
to be connected to the unit.

26. SOLUTION PRESSURE

This selector valve allows the technician to
switch from high pressure to low pressure by
moving the handle to the up position. The high
pressure circuit is activated allowing the unit to
be used as a pressure washer by positioning
the valve handle to the down position. The low
pressure circuit is activated allowing the unit to
be used for carpet cleaning.

This manual is related to the following products: