A) 3, Detail a a 2. 7, A) 4. b) 4. b) – Ouellet OVN User Manual
Page 3
INSTALLATION INSTRUCTION
RECESSED WALL MOUNTING STEPS
or
SURFACE WALL MOUNTING STEPS
by removing the front cover
1. Use the template provided with the heater.
a) Recess wall mounting
- Provide a minimum opening of 2 5/8 in. (67 mm) deep.
HOLE MUST BE CUT PRECISELY.
- Allow 4 in. (102 mm) minimum below heater.
Recommended installation height is 12 in. (305 mm)
below the heater for a better temperature regulation.
b) Surface wall mounting
If you have decided to remove the front cover for a surface
wall mounting installation, follow step 1 of the SURFACE
WALL MOUNTING STEPS without removing the front
cover.
2. Remove the front cover by unscrewing the 2 screws
at the bottom and by sliding the front cover upwards.
3. Disconnect the electronic thermostat from the casing
by pressing the central tab of the black plastic connector.
Put the front cover on a clean surface.
4. a) For an installation with “Loomex” fl exible wire,
use the single-screw wire holder by unscrewing the screw,
make the connections and screw back the wire holder.
Do not let more than 12 in. (305 mm) of loose wire between
the heater and the wall.
b) For “BX” cable,
use the appropriate knock-out (back or bottom of the heater)
with a connector (not supplied). Remove the protection plate
(4 screws), make the connections and put the protection
plate back (4 screws).
5. a) Recessed wall mounting
Install the casing in the wall opening using the recessed
mounting holes on the side or the front of the casing.
Do not try to force the casing in the opening.
b) Surface wall mounting
If you have decided to remove the front cover for
a surface wall mounting installation, follow step 3 and 4
of
the
SURFACE WALL MOUNTING STEPS
without removing the front cover.
6. Reconnect the electronic thermostat to the casing
by cliping both parts of the black plastic connector together.
Replace
the
fl at cable in the wire clips.
7. Put the front cover back by sliding it downwards.
The 2 tabs of the front cover fi t into the 2 slots of the casing.
Screw back the 2 bottom screws.
8. Test the heater by pressing the “Hour-glass” button to activate
the boost heating mode. It is possible that a slight heating smell
emerges from the grilles, which is totally normal and will stop
after a few minutes of operation.
Template provided
1. a)
11 3/16’’
284 mm
14 5/8’’
371 mm
4’’ (102 mm)
Minimum
12’’ (305 mm)
Recommended
5. a)
5. a)
5. a)
5. a)
3.
&
6.
2.
&
7.
Detail A
A
2.
7.
Wall opening
2 5/8’’ (67 mm)
minimum depth
Figure of Recessed wall mounting
or Surface wall mounting installation by removing the front cover
4. a)
4. b)
4. b)