INSTALLATION INSTRUCTION

RECESSED WALL MOUNTING STEPS

or

SURFACE WALL MOUNTING STEPS

by removing the front cover

1. Use the template provided with the heater.

a) Recess wall mounting

- Provide a minimum opening of 2 5/8 in. (67 mm) deep.

HOLE MUST BE CUT PRECISELY.

- Allow 4 in. (102 mm) minimum below heater.

Recommended installation height is 12 in. (305 mm)

below the heater for a better temperature regulation.

b) Surface wall mounting

If you have decided to remove the front cover for a surface

wall mounting installation, follow step 1 of the SURFACE

WALL MOUNTING STEPS without removing the front

cover.

2. Remove the front cover by unscrewing the 2 screws

at the bottom and by sliding the front cover upwards.

3. Disconnect the electronic thermostat from the casing

by pressing the central tab of the black plastic connector.

Put the front cover on a clean surface.

4. a) For an installation with “Loomex” fl exible wire,

use the single-screw wire holder by unscrewing the screw,

make the connections and screw back the wire holder.

Do not let more than 12 in. (305 mm) of loose wire between

the heater and the wall.

b) For “BX” cable,

use the appropriate knock-out (back or bottom of the heater)

with a connector (not supplied). Remove the protection plate

(4 screws), make the connections and put the protection

plate back (4 screws).

5. a) Recessed wall mounting

Install the casing in the wall opening using the recessed

mounting holes on the side or the front of the casing.

Do not try to force the casing in the opening.

b) Surface wall mounting

If you have decided to remove the front cover for

a surface wall mounting installation, follow step 3 and 4

of

the

SURFACE WALL MOUNTING STEPS

without removing the front cover.


6. Reconnect the electronic thermostat to the casing

by cliping both parts of the black plastic connector together.

Replace

the

fl at cable in the wire clips.

7. Put the front cover back by sliding it downwards.

The 2 tabs of the front cover fi t into the 2 slots of the casing.

Screw back the 2 bottom screws.

8. Test the heater by pressing the “Hour-glass” button to activate

the boost heating mode. It is possible that a slight heating smell

emerges from the grilles, which is totally normal and will stop

after a few minutes of operation.

Template provided

1. a)

11 3/16’’

284 mm

14 5/8’’

371 mm

4’’ (102 mm)

Minimum

12’’ (305 mm)

Recommended

5. a)

5. a)

5. a)

5. a)

3.

&

6.

2.

&

7.

Detail A

A

2.

7.

Wall opening

2 5/8’’ (67 mm)

minimum depth

Figure of Recessed wall mounting

or Surface wall mounting installation by removing the front cover

4. a)

4. b)