2

READ AND SAVE THESE INSTRUCTIONS.

BEFORE INSTALLATION

WARNING!

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:

CAUTION

Figure 1

Floor

Cooking

Equipment

Cooking area

Do not install above

or inside this area

45

45

1. Use this unit in the manner intended by the manufacturer. If you have any

questions, please contact the manufacturer .

2. Before servicing or cleaning unit, switch power off at service panel and lock the

service disconnecting means to prevent power from being switched on accidentally.

When the service disconnecting means cannot be locked, securely fasten a

prominent warning device, such as a tag, to the service panel.

3. Installation work and electrical wiring must be done by qualified person(s) in

accordance with all applicable codes and standards, including fire-rated construction.

4. Sufficient air is needed for proper combustion and exhausting of gases through

the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the

heating equipment manufacturer’s guideline and safety standards such as those

published by the National Fire Protection Association (NFPA), and the American

Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and

the local code authorities.

5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and

other hidden utilities.

6. Ducted fans must always be vented to the outdoors.

7. If this unit is to be installed over a tub or shower, it must be marked as appropriate

for the application and be connected to a

GFCI (Ground Fault Circuit Interrupter) –

protected branch circuit.

8. NEVER place a switch where it can be

reached from a tub or shower.

9. This fan must be properly grounded.

10. Do not use in the cooking area (Figure. 1).

11.Do not block the air intakes or exhaust.

12. Power supply wiring is to be No. 14 AWG wire or larger (suitable for at least

90C (190F) ).

13. Not for use outdoors.

14. For the lighted unites, use only PLC type 26W lamps and a maximum of 4W

night lamp for lighting.(SBF80L, SBF110L)

15. The fan must not be installed in a ceiling with an “R” rating greater than 40.

16. The fan is type IC (Inherently Protected).

17. To reduce the risk of injury, install the fan at least 2.1m (7 feet) above the floor.

18. Acceptable for use over a shower or tub when installed in a GFCI protected

branch circurt.

19. The fan should not be turned on and off rapidly nor should it be left running

continuously.

20. Do not clean the fan with corrosive chemicals nor water in excess of 60C

(140F).

21. If the fan is not operating properly, shut the power off immediately, and have

a certified inspect it and have it serviced as required.

22. These fan must be mounted to structural members that are strong enough to

support the fan’s weight.

23. Do not allow foreign objects to enter the fan; this could result in electric shock

or fan damage.

1. For general ventilating use only. Do not use to exhaust hazardous or explosive

materials and vapors.

2. This product is designed for installation in flat ceilings only. Do not install it in a

sloping ceiling or in a wall.

3. To avoid motor bearing damage and noisy unbalanced impellers keep

construction material / dust from entering the fan.

4.Please read specification label on the product for further information and

requirements.

5."WARNING":To Reduce The Risk Of Fire Or Electric Shock,Do Not Use This

Fan With Any Solid-State Speed Control Device.

Read these instructions carefully before installing or using this product!