beautypg.com

Dwyer instruments, inc – Dwyer WTDL User Manual

Page 2

background image

CONNECTING THE DATA LOGGER
1. Plug the receiver into the USB port on the computer.
2. Plug additional receivers into the wall using the AC adapter.
3. Turn the data logger on.
4. A WTDL icon will automatically appear in the software showing the device is
recognized.

STARTING THE DEVICE
1. Highlight the device in the RFLogNET software.
2. Click the Claim Icon.
3. Click the Start button.

4. To view data in real time, click the Stream button on the RFLogNET window.
5. A Dwyer graphing software window will open up showing real time data from the
device.

**For more information on using the WTDL-RX software, please consult the software
manual found on the CD.

BATTERY
The battery is user replaceable and has a typical battery life of 2 years. To replace the
battery, remove the backside of the data logger and take the battery out. Replace the
backside of the data logger. Shorter sample rates will considerably shorten the battery
life. To preserve battery life, it is recommended to use the longest practical sampling
rate, and when the logger is not in use, turn the logger off.

MAINTENANCE/REPAIR
Upon final installation of the Series WTDL, no routine maintenance is required. The
Series WTDL is not field serviceable and should be returned if repair is needed. Field
repair should not be attempted and may void warranty.

WARRANTY/RETURN
Refer to “Terms and Conditions of Sales” in our catalog and on our website. Contact
customer service to receive a Return Goods Authorization number before shipping the
product back for repair. Be sure to include a brief description of the problem plus any
additional application notes.

DWYER INSTRUMENTS, INC.

Phone: 219/879-8000

www.dwyer-inst.com

P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A.

Fax: 219/872-9057

e-mail: [email protected]

©Copyright 2013 Dwyer Instruments, Inc.

Printed in U.S.A. 10/13

FR# R6-444062-00

The WTDL-RX can transmit up to 2000’ outdoors and 500’
indoors. If the distance is greater than 500’ indoors or 2000’

outdoors, or there are obstacles that need to be maneuvered around, setup
additional WTDL-RX receivers as needed.

NOTICE

Figure 1: Backside of data logger showing power switch

(0 is off, 1 is on)

Figure 2: RFLogNet Data Logger Configurator

PC-WTDL_SSS-1000 10/4/13 10:12 AM Page 2