Dwyer DPMF User Manual
Page 2
OPERATION
Selecting Decimal Point Position
Four decimal point positions are available on the digital panel meter.
Move the jumper to correspond the desired decimal point. See Figure 1.
Figure 1
Setting Min/Max Display Value J1, J2, J3 (see Figure 2 & 3):
If:
The minimum display is ≤0 or minimum display is > 0 and the (maximum
display minimum display) ≥ 5;
Then:
J1, J2 & J3 should be all set to the top jumper (see Figure 2).
Figure 2
If:
The minimum display is > 0 and the (maximum display minimum
display) <5;
Then:
J1, J2 & J3 should all be set to the bottom jumper (see Figure 3).
Figure 3
MAINTENANCE/REPAIR
Upon final installation of the Series DPMF, no routine maintenance is
required. The Series DPMF is not field serviceable and should be
returned if repair is needed. Field repair should not be attempted and
may void warranty.
WARRANTY/RETURN
Refer to “Terms and Conditions of Sale” in our catalog and on our
website. Contact customer service to receive a Return Goods
Authorization number before shipping the product back for repair. Be
sure to include a brief description of the problem plus any additional
application notes.
©Copyright 2014 Dwyer Instruments, Inc.
Printed in U.S.A. 5/14
FR# R2-444115-00 Rev. 1
DWYER INSTRUMENTS, INC.
Phone: 219/879-8000
www.dwyer-inst.com
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A.
Fax: 219/872-9057
e-mail: [email protected]
A
J3
J2
J1
B
A
J3
J2
J1
B
•
•
•
•