MECHANICAL STAGE
All sensors come with a 3.3 ft (1 m) cable and a mounting nut.
The sensor can be mounted on brackets or cut outs of your own
design, or you can use the fixed and adjustable mounting
bracket accessories, which are shown below. (See Figure 3).

ELECTRICAL STAGE - WIRING:
Series ILA sensors are available as either two-wire or four-wire
units. J-type and 0 to 50 mV output models transmit the target
temperature as a 0-50 mV or J-Type thermocouple outputs plus
the internal sensor temperature as a 4-20 mA output. This
second 4 to 20 mA output can be used to ensure that the sensor
is being operated within the correct ambient temperature limits
and prevent damage caused by overheating or overcooling. It
can also be used to give an approximate indication of the air
temperature surrounding the sensor.

Note: The cable shield must be grounded at only one point,
which is usually at the controller/indicator. However, it can be
done at a junction box or other suitable location in the field area.

Operation
Once the sensor is in position and the appropriate power, air,
water and cable connections are secure the system is ready for
continuous operation by completing the following simple steps:
1. Turn on the power supply.
2. Turn on the meter, chart recorder or controller.
3. Read/monitor the temperature.

Important
Be aware of the following when using the sensor:
• If the sensor is exposed to significant changes in ambient

temperature (hot to cold or cold to hot) allow 20 minutes for
the temperature to stabilize before taking or recording
measurements.

• Do not operate the sensor near large electromagnetic fields

(e.g.
around arc welders or induction heaters).

• Wire must be connected only to the appropriate terminals.

MAINTENANCE
Our customer service representatives are available for
application assistance, calibration repair, and solutions to
specific problems. Contact our customer service representatives
before returning any equipment, in many cases, problems can
be solved over the telephone. If the sensor is not performing, as
it should, try to match the symptom to the problem below. If the
table does not help, call Dwyer for further advice.

2x Mounting holes M4 clearance

Fixed Bracket

25

10

40

50

15

26

16 DIA

2

2x Mounting holes M4 clearance

Fixed Bracket

25

10

40

50

15

26

16 DIA

2

FIGURE 3

Symptom

No Output

Erroneous

Temperature

Erroneous

Temperature

Erroneous

Temperature

Probable Cause

No power to sensor

Incorrect wire connection

Faulty sensor

Field of view obstruction

Solution

Check power supply

Check wire color codes

Verify cable continuity

Remove obstruction

TROUBLE SHOOTING

+

-

-

+

Display/Controller

4-20mA = Target

4-20mA

Temperature

Power Supply

+

-

-

+

4-20mA = Sensor

Temperature

Power Supply

-

+

mV/TC = Target

Temperature

Two-wire units (4 to 20 mA models)

Four-wire units (J Type or 0 to 50 mV Outputs)

OP-

OP+

PWR+

PWR-

PWR+

PWR-

Display/Controller

Display/Controller

4-20mA