beautypg.com

Dwyer TTE User Manual

Page 2

background image

INSTALLATION
1. Location:
Select a location where the temperature of the

transmitter will be between 0 and 158°F. Distance from
the receiver is limited only by total loop resistance.

2. Position: The transmitter is not position sensitive. Units

with the optional display should be mounted for ease of
viewing the display.

3. Electrical Connection:

Wire Length - The maximum length of wire connecting
the transmitter and receiver is a function of wire size and
receiver resistance. Wiring should not contribute more
than 10% of the receiver resistance to total loop
resistance. For extremely long runs (over 1000 feet),
choose receivers with lower resistance to minimize the
size and cost of connecting leads.

Current (4-20 mA) Output Operation
An external power supply is required. See Fig. A for diagram
of the connection of the power supply, transmitter and
receiver. The range of appropriate receiver load resistance
(RL) for the DC power supply voltage available is expressed
by the formula:

Shielded cable is recommended for control loop wiring.

Explosion-Proof Installation Notes:

1. Install in accordance with any applicable national electric

code.

2. Plug unused conduit openings. Plug must engage a

minimum of 5 threads.

3. Use a conduit seal within 18 inches of conduit entry.
4. Disconnect power before servicing.

Electrical connections to the RTD Transmitter are made to
the terminal block located inside the housing. Unscrew and
remove the cover. Wire as shown in FIG. B.

Temperature Range Selection
The RTD Transmitter has 7 built in temperature ranges and
a user settable range that are selectable by setting the Dip
Switch located inside the housing (Fig C). Switches 2, 3,
and 4 are used to set the range. To set the desired range,
unscrew and remove the cover and set the Dip Switch
according to the following table:

DIP SWITCH

Selectable Ranges

2

3

4

40 to 90°F (4.4 to 32.2°C)

OFF

OFF

OFF

-20 to 140°F (-28.9 to 60°C)

ON

OFF

OFF

0 to 100°F (-17.8 to 37.8°C)

OFF

ON

OFF

30 to 240°F (-1.1 to 115.6°C)

ON

ON

OFF

32 to 212°F (0 to 100°C)

OFF

OFF

ON

32 to 122°F (0 to 50°C)

ON

OFF

ON

-30 to 65°C (-1.1 to 18.3°C)

OFF

ON

ON

User Settable

ON

ON

ON

E-90-TTE:Model PHO-1 12/22/08 2:04 PM Page 2