2off, F-2000, I.p.s. pipe (meets astm-d-1785) – Blue-White F-2000 – Sensor User Manual
Page 17: Page 16, 6 calibration constants, Page 17, Molded inline bodies (male npt connection), Saddle mount models (pipe insertion connection), Machined inline bodies (female npt connection), Saddle models (pipe insertion connection)

F-2000
Page 16
I.P.S. PIPE (Meets ASTM-D-1785)
Step 5
The Total Decimal Point screen is selected.
! The Total 2 screen is where you enter your Decimal Point Factor for your totalizer.
Use the information you calculated on D , on Page 14, Step 5. Move the decimal point by pressing the
until
t
the decimal point is in the desired location. Then press . Ex. 00000
Step 6
The Front Panel Clear Total Button Enable / Disable screen is
selected. Factory default = OFF (disabled)
! The Total 3 screen gives you the option to turn on or off the clear total button function. It was designed to prevent
the user from making the mistake of clearing the totalizer screen. By pressing the you can scroll through the
on and off mode. Press once you have made your selection.
Step 7
Press and hold down
for at least 1.25 seconds to exit the programming mode.
TOTAL
CLEAR
ENTER
TOTAL
CLEAR
ENTER
ENTER
000000
TOTAL
2
Off
TOTAL
3
7.2.6 Calibration Constants
Pipe Size
(MM)
PN
Rating
Pipe I.D. (MM)
Flow Range
(LPM)
K-Factor
(Pulse/L)
Rate Scale
Factor (Sr)
Rate Display
Decimal Point
Total Scale
Factor (St)
Total Display
16
10
10
16
50
50
63
63
45.2
42.6
57.0
53.6
70.0 - 700.0
70.0 - 700.0
110 - 1100
110 - 1100
16.561
20.719
10.522
11.830
36.2297
28.9588
05.7023
05.0720
0000.0
0000.0
00000
00000
00.0604
00.0483
00.0950
00.0845
00000
00000
00000
00000
16
10
10
16
90
90
110
110
81.4
76.6
99.4
93.6
230 - 2300
230 - 2300
350 - 3500
350 - 3500
5.294
5.944
2.942
3.107
11.3335
10.0944
20.3969
19.3133
00000
00000
00000
00000
00.1889
00.1682
00.3399
00.3219
00000
00000
00000
00000
16
10
10
160
160
200
144.6
136.2
180.8
720 - 7200
720 - 7200
1150 - 11500
1.386
1.574
0.927
43.2782
38.1081
64.7077
00000
00000
00000
00.7213
00.6351
01.0785
00000
00000
00000
RATE 1
RATE 2
TOTAL 1
TOTAL 2
Standard Flow Range - LPM (liters per minute)
Molded Inline Bodies (Male NPT connection)
METRIC PIPE PN10 & PN16 (Meets DIN 8062)
Note:
The values in the following tables are based on laboratory testing of nominal pipe dimensions. The F-2000 sensor is factory calibrated to ±1%
of full scale linearity. Your actual accuracy will vary based on your pipe I.D. And other installation factors.
Saddle Mount Models (Pipe Insertion connection)
Pipe Size
(in.)
Pipe Sch.
Inline
Inline
Inline
Inline
3/8
1.0
Body I.D. (In.)
0.375
0.500
0.660
0.840
Flow Range
(GAL/Min)
.800 - 8.000
2.00 - 20.00
3.00 - 30.00
5.00 - 50.00
K-Factor
(Pulse/GAL)
1456.31
1034.48
612.25
338.60
Rate Scale
Factor (Sr)
41.2000
05.8000
09.8000
17.7200
Rate Display
Decimal Point
00.000
000.00
000.00
000.00
Total Scale
Factor (St)
00.0069
00.0097
00.0163
00.0295
Total Display
Decimal Point
0000.0
0000.0
0000.0
0000.0
RATE 1
RATE 2
TOTAL 1
TOTAL 2
3/8” - 1” pipe sizes - Standard Range #1 - GPM (gallons per minute)
1 /2
3/4
16
200
170.2
1150 - 11500
1.008
59.5501
00000
00.9925
00000
10
250
226.2
1700 - 17000
0.565
106.232
00000
01.7705
00000
10
315
285.0
2700 - 27000
0.353
170.003
00000
02.8334
00000
RATE 1
Pipe Size
(in.)
Pipe Sch.
Inline
Inline
Inline
Inline
3/8
1/2
3/4
1.0
Body I.D. (In.)
0.218
0.250
0.375
0.500
Flow Range
(GAL/Min)
.400 - 4.000
.500 - 5.000
.800 - 8.000
2.00 - 20.00
K-Factor
(Pulse/GAL)
2926.83
2419.35
1518.99
1034.48
Rate Scale
Factor (Sr)
20.5000
24.8000
39.5000
05.8000
Rate Display
Decimal Point
00.000
00.000
00.000
000.00
Total Scale
Factor (St)
00.0034
00.0041
00.0066
00.0097
Total Display
Decimal Point
0000.0
0000.0
0000.0
0000.0
3/8” - 1” pipe sizes - Low Range #2 - GPM (gallons per minute)
RATE 2
TOTAL 1
TOTAL 2
F-2000
Page 17
Pipe Size
(in.)
Pipe Sch.
Inline
Inline
Inline
Inline
3/8
1/2
3/4
1.0
Body I.D. (In.)
0.218
0.250
0.375
0.500
Flow Range
(GAL/Min)
.400 - 4.000
.500 - 5.000
.800 - 8.000
2.00 - 20.00
K-Factor
(Pulse/GAL)
3468.21
2631.58
1469.87
985.22
Rate Scale
Factor (Sr)
17.3000
22.8000
40.8200
06.0900
Rate Display
Decimal Point
00.000
00.000
00.000
000.00
Total Scale
Factor (St)
00.0029
00.0038
00.0068
00.0102
Total Display
Decimal Point
0000.0
0000.0
0000.0
0000.0
Low Flow Range #2 - GPM (gallons per minute)
RATE 1
RATE 2
TOTAL 1
TOTAL 2
Pipe Size
(in.)
Pipe Sch.
Inline
Inline
Inline
Inline
3/8
1/2
1.0
Body I.D. (In.)
0.375
0.500
0.750
1.000
Flow Range
(GAL/Min)
.800 - 8.000
2.00 - 20.00
4.00 - 40.00
6.00 - 60.00
K-Factor
(Pulse/GAL)
1469.87
985.22
471.70
204.08
Rate Scale
Factor (Sr)
40.8200
06.0900
12.7200
29.4000
Rate Display
Decimal Point
00.000
000.00
000.00
000.00
Total Scale
Factor (St)
00.0068
00.0102
00.0212
00.0490
Total Display
Decimal Point
0000.0
0000.0
0000.0
0000.0
RATE 1
RATE 2
TOTAL 1
TOTAL 2
Standard Flow Range #1 - GPM (gallons per minute)
Machined Inline Bodies (Female NPT connection)
3/4
Inline
Inline
2.0
1.500
1.900
15.0 - 150.0
30.0 - 300.0
86.120
48.884
6.9670
12.2740
0000.0
0000.0
00.0116
00.0205
00000
00000
1-1/2
Inline
Inline
2.0
1.250
1.500
10.0 - 100.0
15.0 - 150.0
155.00
89.020
3.8710
6.7401
0000.0
0000.0
00.0065
00.0112
00000
00000
1-1/2
Saddle Models (Pipe insertion connection)
Standard Flow Range - GPM (gallons per minute)
RATE 1
RATE 2
TOTAL 1
TOTAL 2
80
40
40
80
1.5
1.5
2.0
2.0
1.610
1.500
2.067
1.939
15.0 - 150.0
15.0 - 150.0
30.0 - 300.0
30.0 - 300.0
86.580
102.04
50.850
58.820
06.9300
05.8800
11.7994
10.2006
0000.0
0000.0
0000.0
0000.0
00.0116
00.0098
00.0197
00.0170
00000
00000
00000
00000
80
40
40
80
3.0
3.0
4.0
4.0
3.068
2.900
4.026
3.826
60.0 - 600.0
60.0 - 600.0
100 - 1000
100 - 1000
21.820
24.000
11.8577
12.7659
27.4977
25.0000
05.0600
04.7000
0000.0
0000.0
00000
00000
00.0458
00.0417
00.0843
00.0783
00000
00000
00000
00000
80
40
40
80
6.0
6.0
8.0
8.0
6.065
5.761
7.981
7.625
250 - 2500
250 - 2500
400 - 4000
400 - 4000
5.3507
5.5738
2.985
2.940
11.2135
10.7647
20.1000
20.4082
00000
00000
00000
00000
00.1869
00.1794
00.3350
00.3401
00000
00000
00000
00000
Pipe Size
(in.)
Pipe Sch.
Pipe I.D. (In.)
Flow Range
(GAL/Min)
K-Factor
(Pulse/GAL)
Rate Scale
Factor (Sr)
Rate Display
Decimal Point
Total Scale
Factor (St)
Total Display
Decimal Point
80
40
40
80
10.0
10.0
12.0
12.0
10.020
9.564
11.938
11.376
600 - 6000
600 - 6000
800 - 8000
800 - 8000
1.594
1.845
1.116
1.296
37.6412
32.5203
53.7634
46.2963
00000
00000
00000
00000
00.6274
00.5420
00.8961
00.7716
00000
00000
00000
00000
Pipe Size
(in.)
Pipe Sch.
Inline
Inline
Inline
Inline
1-1/2
1-1/2
1-1/2
2.0
Flow Range #
3
4
5
3
Flow Range
(GAL/Min)
6.00 - 60.00
2.00 - 20.00
1.00 - 10.00
10.0 - 100.0
K-Factor
(Pulse/GAL)
217.39
1076.60
1283.88
162.47
Rate Scale
Factor (Sr)
27.6002
5.5731
4.6733
3.6930
Rate Display
Decimal Point
000.00
000.00
000.00
0000.0
Total Scale
Factor (St)
00.0460
00.0093
00.0078
00.0062
Total Display
Decimal Point
0000.0
0000.0
0000.0
00000
Low Flow Ranges #3, 4, 5, 6 - GPM (gallons per minute)
RATE 1
RATE 2
TOTAL 1
TOTAL 2
Inline
Inline
2.0
4
5
6.00 - 60.00
4.00 - 40.00
224.67
493.83
26.7058
12.1500
000.00
000.00
00.0445
00.0203
0000.0
0000.0
2.0
Inline
6
2.00 - 20.00
950.87
6.3100
000.00
00.0105
0000.0
2.0
Pipe Size
(in.)
Pipe Sch.
Inline
Inline
Inline
1-1/2
2
2
Flow Range #
3
2
3
Flow Range
(GAL/Min)
10.0 - 100.0
6.00 - 60.00
10.0 - 100.0
K-Factor
(Pulse/GAL)
156.94
196.40
162.16
Rate Scale
Factor (Sr)
3.8231
30.5499
3.7000
Rate Display
Decimal Point
0000.0
000.00
0000.0
Total Scale
Factor (St)
00.0637
00.0509
00.0617
Total Display
Decimal Point
0000.0
0000.0
0000.0
1-1/2” - 2” pipe sizes - GPM (gallons per minute)
RATE 1
RATE 2
TOTAL 1
TOTAL 2
Molded Inline Bodies (Male NPT connection) - continued
Inline
Inline
Inline
1-1/2
1-1/2
2
1
2
1
4.00 - 40.00
6.00 - 60.00
4.00 - 40.00
466.20
192.93
468.75
12.8700
31.0994
12.8000
000.00
000.00
000.00
00.0215
00.0518
00.0213
0000.0
0000.0
0000.0
Inline
2
4
20.0 - 200.0
67.416
8.9000
0000.0
00.1483
0000.0
40
80
2.5
2.5
2.469
2.323
40.0 - 400.0
40.0 - 400.0
34.8635
39.200
17.2010
15.3061
0000.0
0000.0
00.0287
00.0255
00000
00000