Stby – Blue-White CHEM-PRO C3 ProSeries Diaphragm Pump User Manual
Page 14

Page 14
Page 15
Used to manually control speed of pump.
Use UP and DOWN arrows to adjust speed while pump is running.
To select exact run speed, follow steps below.
With pump operating in manual operation, pump speed can be changed at anytime by using UP or DOWN arrows during operation.
8.0
Manual Operation
Runtime Screen Shot 1
Displays motor speed percentage.
Pump Running in Manual Operation
35.0
SPEED
35.0
REMOTE
Runtime Screen Shot 2
Displays motor speed percentage.
Pump Running in Manual Operation with Remote Start /
Stop enabled (see page 11).
stby
REMOTE
Runtime Screen Shot 3
Displays ‘Stand-By’ status with Remote start/stop enabled
and waiting for signal to start.
Caution, pump can start up at anytime in this condition.
Press STOP button before performing maintenance.
SPEED
SPEED
9.0
DFD (Diaphragm Failure Detection)
Chem-Pro® is equipped with a Diaphragm Failure Detection System which is designed to stop pump and provide
an output alarm in event diaphragm should rupture and chemical enters pump head. Pump will detect a chemical
with a conductivity reading greater than 500 microsiemens. Chemicals with a conductivity of less than 500
microsiemens will not be detected.
This system is capable of detecting presence of a large number of chemicals including Sodium Hypochlorite
(Chlorine), Hydrochloric (muriatic) Acid, Sodium Hydroxide, and many others. System will not be triggered by
water (rain, condensation, etc.) or lubricants.
If system has detected chemical, pump diaphragm must be replaced and pump head must be thoroughly cleaned.
Failure to clean pump head will void warranty.
If DFD alarm occurs, pump will stop, close an alarm output, and screen will flash DFD with an alarm icon.
Chem-Pro
Chem-Pro
®
®
DFD
DFD Sensors
Diaphragm
Diaphragm
Outlet
(discharge)
Built -In DFD
Diaphragm Failure
Detection
Inlet
(suction)
Pump
Head