Multi-parameter transmitter user’s manual – Metex SharkTX Multi-Parameter Transmitters User Manual
Page 4

M
Ω
/cm
3
0 to 19.99 0.01
uS/cm
3
0 to 2.000 0.01
0 to 20.00 0.1
0 to 200.0 0.1
0 to 5000
1.0
mS/cm
3
0 to 20.00 10
0 to 200.0 50
Section I - Specifications
Page 2
MULTI-PARAMETER TRANSMITTER USER’S MANUAL
Section I - Specifications
pH
ORP
Conductivity
Flow
Display
2 x 16 alpha-numeric LCD display
Power Requirements
4 to 20mA, Loop Powered, 16 to 32 VDC
Flow:
0 to 9999 with selectable
flow rate units
pH:
0.01 to 14.00
ORP: -1999 to +1999mV
Volume: 0 - 999 with Auto Range
Measuring Range
(Dependent on sensor)
Flow rate units: Gallons (GP), Cubic
Temp: 0 to 100°C or
Temp: 0 to 100°C or
Feet (CF), Liters (LP), Cubic Meters
32° to +212°F
32° to +212°F
(CM), custom by entering factor
related to Gallons
Time units: Seconds (S), Minutes (M)
Temp:
0 to 100°C or 32° to +212°F Hours (H)
Automatic or Manual
Temperature
Automatic or Manual
Not required
User selectable temperature
Not required
Compensation
0 - 100°C (32° to +212°F)
compensation slope 0.0 to 10.0%/°C.
0 to 100°C (32° to +212°F)
Temperature Unit
°C or °F
Not required
Temperature Sensor
User selectable: 300
Ω
NTC Thermistor, 3000
Ω
NTC Thermistor or Pt. 1000 RTD
Not required
Auto-Calibration
Manual Calibration
Dry Calibration
Calibration Modes
Manual Calibration
Temperature Calibration
Sample Calibration
K factor Input
Temperature Calibration
Temperature Calibration
Ambient Conditions
Temperature: -20°C to +60°C or -4°F to +140°F Humidity: 0 to 90% RH (non-condensing)
Sensor to Transmitter
Differential Sensor: 3000 ft
300 ft
2000 ft
Distance
Combination Sensor: 10 ft
Analog Output
4 to 20mA
Isolated Output, Range expand 0 to 100% of full scale (min segment 10% of full scale), max. load 800
Ω
Memory Back-up
All user settings are retained indefinitely in memory (EEPROM)
SHARK
TX
Enclosure: NEMA 4X, 1/4 DIN, polycarbonate enclosure with two 1/2” conduit holes
Mechanical
SHARK
TXP
Enclosure: NEMA 4X front panel, 1/4 DIN, polycarbonate
SHARK
TX
Mounting: Universal Mounting kit for surface, pipe and panel mount included
SHARK
TXP
Mounting: Panel and DIN rail mount included
Sensor Input
Probe: -600 to +600mV
Probe: -1999 to +1999mV
Cell: 0 to 9999
Ω
Paddle: 0 to 2000Hz
Temp. Sensor: 0 to 9999
Ω
Temp. Sensor: 0 to 9999
Ω
Temp. Sensor: 0 to 9999
Ω
Invalid Entries
Invalid entries cannot be stored
Manual Test Mode
Process value can be simulated with arrow keys to verify correct setup of output
Output Hold
4 to 20mA output is placed on hold when the transmitter is in Menu mode
Recall data from last
Recall data from last calibration, calibration mode,
calibration, calibration buffer
Calibration Data
1st & 2nd accepted buffer value and probe mV output,
accepted value, and cell
Recall store K factor.
calibration temperature, calibration slope, and probe
resistance, calibration
efficiency
temperature
Auto Return
User selectable auto return if the transmitter is left in menu mode for more than 10 min.
Display Damping
User can select rate at which the transmitter updates display. Enables display damping of unstable process
Net Weight
SHARK
TX
: 0.71 lbs (0.32 kg)
SHARK
TXP
: 0.25 lbs (0.12 kg)
Approvals
ULC (pending)