TECHNICAL DATA

22

LS 6600

www.krohne.com

03/2013 - 4001367702 - MA LS 6600 R02 en

Materials

Sensor housing

Stainless Steel 1.4404 / 316L

Process connection

Sensor insulation

Virgin PEEK, FDA conform

Electrical connection

Plug M12

Process connections

Standard

Hygienic G½; standard G½; G1 and reverse G½

Other

For other hygienic process connections, e. g. Tri-clamp, 11851, Varivent see

data sheet "Accessories".

Electrical connections

Power supply

Non-Ex / Ex nA / Ex ta: 12…30 VDC, 35 mA max.

Ex ia: 24…30 VDC

Power consumption

1.1 W

Power-up time

< 2 s

Reaction time

Max. 0.2 s

Damping

0...10 s

Cable entry

M12 (4 pole Lumberg)

Output

Output (active)

Max. 20 mA, short-circuit and high-temperature protected

Output type

PNP or NPN

Output polarity

See drawing in chapter "Electrical connection".

Active "Low"

NPN; (-VDC + 1.5 V) ± 0.5 V; R

load

= 10 kOhm

Active "High"

PNP; (VDC - 1.5 V) ± 0.5 V; R

load

= 10 kOhm

Factory settings

Measure: ε

r

> 2; damping: 0.1 s

Off leak current

±

100 μA max.

Approvals and certifications

CE

This device fulfils the statutory requirements of the EC directives.

The manufacturer certifies successful testing of the product by applying the

CE marking.

ATEX

Ex ia IIC T5, ATEX II 1G (in preparation)

Ex nA II T5, ATEX II 3G (in preparation)

Ex ta IIIC T100 Da, ATEX II 1D (in preparation)

Other standards and approvals

Other standards and approvals

Other standards and approvals

Other standards and approvals

Electromagnetic compatibility (EMC)

EN 61326

Vibration resistance

IEC 60068-2-6, GL test 2

Hygiene

3A for hygienic G½, FDA conform materials

.book Page 22 Tuesday, March 12, 2013 11:44 AM