4.5 Configuration tool

The configuration tool can be ordered optionally to configure the LS 6600 switches.

Scope of delivery:

• Interface unit
• CD with software and product drivers (DTM)
• USB cable
• Cable with M12 connector

The configuration tool connects the LS 6600 with a computer. With the corresponding software,
it is possible to get an online communication with the LS 6600.

By using this tool, device information like serial number, switching point range and tag numbers
are displayed on the computer. Settings as switching point and damping can be changed.

Self-learning function for the contact output is possible as well as reset function to the default
values of the switching point.

By fine-tuning of the switching point settings, LS 6600 could differentiate between various
products which are covering the sensor. In other words, the device could be set to trigger on a
specific product and ignore a second product. Basis for this would be a different ε

r

value of the

two products.

DANGER!
Disconnect the power supply before connecting the configuration tool to the switch!

Figure 4-1: Electrical connection of configuration tool

1 M12 plug

INFORMATION!
Ambient temperature range is 0...+50°C / +32...+122°F.

DANGER!
The configuration tool cannot be connected to the LS 6600 within the hazardous area. For
programming, remove the device out of this area.