Operation

5.1 Start-up

Before connecting to power, please check that the system has been correctly installed.
This includes:

• The device must be mechanically safe and mounted in compliance with the regulations.
• Check the leak-tightness at the sleeve.
• Make sure that the M12 plug is properly connected.
• The power connections must have been made in compliance with the regulations.
• Check that the electrical operating data of the power supply are correct.

• Switching on the power.

i

Check for correct switching function.

5.2 Fault diagnosis and corrective action

Fault

Cause

Action / elimination

LED not "on"

Sensor cap not in contact with

liquid product

-

Supply voltage < 12 V, permittivity

too low

Measure voltage at pin 1 and 3

No switching output

Cable break

Check continuity of cables

Incorrect polarity of supply

Reverse terminal 1 and 3

Short-circuit

Check wiring