Technical data (extract)

Tank height (measuring range)

0.5 to 20 m / 1.6 to 65.6 ft

Measuring accuracy (distance)

from 1m/3ft: + 1cm/0.4” ; from 5m/16ft: + 0.2%

Measured-value resolution

1 mm / 0.04”

Rate of change in level

max. 10 m/min / 32.8 ft/min (tracking speed)

Connecting flanges

Horn antenna/Wave-Guide

DIN 2501 DN 50 to DN 200 / PN 6 to PN 64 and

higher;

Shape C to DIN 2526 or others

ANSI B16.5 2” to 8",

Class 150 lb or 300 lb, RF

Wave-Stick

DN 50...150 or ANSI 2”...6”, dairy DIN 11851

DN 50/65/80, Tri-Clamp 2/3/4”,

SMS 51/63/76 mm, G 1½"

Max. allowable operating pressure

-1 bar (vacuum) to 64 bar / 928 psig higher on
request, depending on version and flange pressure
rating. (see name plate)

LP flange system with horn antenna, Wave-Guide or Wave-Stick without flange plate

-1 bar (vacuum) to +2 bar /29 psig

V96 flange system with horn antenna or Wave-Guide:

Connection:
nominal dia.

Flange rated pressure

PN 16

PN 25

PN 40

PN 64

DN inches bar psig bar psig bar psig bar psig

80 3 16

232

--- --- 40

580 64

928

100 4 16 232 --- --- 38 551 55 797

150 6 16 232 --- --- 34 493 47 681

200 8 16 232 25 362 32 464 45 652

Wave-Stick: max. 16 bar / 232 psig, temperature-dependent:

-20

+150

+100

-1

+1

+16

46 - 0.3·T[°C] bar

temperature T

pressure

+232

[psig] [bar]

+14

-14

+212

+302°F

745 - 2.42·T[°F] psig