beautypg.com

Installation, 3 mounting of 3a marked products – KROHNE BM 500 EN User Manual

Page 13

background image

INSTALLATION

3

13

BM 500

www.krohne.com

12/2013 - 4003176301 - MA BM 500 R02 en

3.3 Mounting of 3A marked products

The 3A mark is valid only when the product is mounted in a 3A marked counterpart and installed
acc. to the installation manual. Use also a 3A marked O-ring or gasket if relevant.

The 3A marked products conform to the 3A sanitary standards criteria. Materials and surfaces
fulfill the FDA demands.

EPDM O-rings supplied with 3A marked products are conform to sanitary standards class II (8%
milk fat).

1 Use only 3A approved counterparts.
2 The inspection hole should be visible and drained. Face it downwards so that possible leaking
can be observed.
3 Mount the device in a self-drained position.
4 Level the inner surface of the pipe with the counterpart.
5 Weld from the inside of the tank, if possible. Welds shall be free from cracks, crevices and
grooves. Weldings should be grinded to R

a

= 0.8 µm.

6 The level meter can be installed on the side of the tank with a bent measuring probe.
7 The level meter can be installed from the bottom of the tank.

Figure 3-3: Mounting of 3A products in pipe installations (A) or tank installations (B)