3.2 General notes on installation

3.3 Mounting restrictions

3.3.1 General installation principles

There are no special installation requirements but you should note the following
points:

• Support the weight of the meter as close to the meter body as possible.
• Mount the meter in such a way to avoid the build up of liquid in the measuring tube.
• Straight runs either side of the meter are not required.
• The use of reducers and other fittings at flanges, including flexible hoses, is allowed but you

should take care to avoid cavitation.

• Avoid extreme pipe size reductions.
• Meters are not affected by crosstalk and can be mounted in series or in parallel.
• Avoid mounting the meter at the lowest point in the pipeline where liquid can collect.

INFORMATION!
Inspect the packaging carefully for damages or signs of rough handling. Report damage to the
carrier and to the local office of the manufacturer.

INFORMATION!
Do a check of the packing list to make sure that you have all the elements given in the order.

INFORMATION!
Look at the device nameplate to ensure that the device is delivered according to your order.
Check for the correct supply voltage printed on the nameplate.

MA_OPTIGAS_4010C_en_140722_4002962702_R02.book Page 9 Tuesday, July 22, 2014 4:30 PM