beautypg.com

Installation – KROHNE OPTIGAS 4010 C EN User Manual

Page 10

background image

3

INSTALLATION

10

OPTIGAS 4010C

www.krohne.com

07/2014 - 4002962702 - MA OPTIGAS R02 en

Mounting positions

1 Avoid mounting the meter with the flow running uphill because it can cause liquid to build up on the supply side of the

meter.

2 Mount the meter with the flow running downhill. This will allow any build up of liquid to drain from the meter.
3 Avoid mounting the meter with the connection box above the meter. This can cause liquid to collect in the measuring

tubes at their lowest point in the meter.

4 Mount the meter with the junction box underneath the meter. This will prevent liquid from collecting in the measuring

tubes.

5 The meter can be mounted vertically but DO NOT mount it so that the flow is uphill. This can cause fluid to build up on

the supply side of the meter.

6 If you are mounting the meter vertically, mount it so that the flow is downhill. This will allow any build up of fluid to

drain from the meter.

MA_OPTIGAS_4010C_en_140722_4002962702_R02.book Page 10 Tuesday, July 22, 2014 4:30 PM