TECHNICAL DATA

6

17

OPTIGAS 4010C

www.krohne.com

07/2014 - 4002962702 - MA OPTIGAS R02 en

When the meter is energised, the drive coil vibrates the measuring tubes causing them to
oscillate and produce a sine wave (3). The sine wave is monitored by the two sensors.

When a fluid or gas passes through the tubes, the Coriolis effect causes a phase shift in the sine
wave that is detected by the two sensors. This phase shift is directly proportional to the mass
flow.

Temperature measurement is made using a Pt500 sensor.

Energised meter

1 Measuring tubes
2 Direction of oscilation
3 Sine wave

Energised meter with process flow

1 Process flow
2 Sine wave
3 Phase shift