TECHNICAL DATA

6

25

GA24

www.krohne.com

02/2011 - 4001229901 MA GA24 R01 en

Measuring span 10 : 1

Flow values 100%

Reference condition:

Water 68°F / Air 68°F - 14.7 psi

Float materials:

1 Stainless Steel or Hastelloy® - 2 PTFE - 3 TFM - 4 Aluminium - 5 Polypropylen (PP)

Materials →

1

2

3

1

3

4

5

1

2

3

4

5

Cone ↓

Flow, water [gph]

Flow, air [scfm]

Max. pressure loss [psi]

N 18.07

DN15

10.6

6.6

3.43

0.93 0.37

0.5

0.31

0.1

0.1

0.03

0.04

0.02

N 18.09

16.6

10.6

5.81

1.36 0.59

1.2

0.43

0.1

0.1

0.04

0.04

0.03

N 18.13

26.4

16.6

9.25

1.86 0.93

0.74

0.74

0.1

0.1

0.04

0.06

0.03

N 19.09

42.3

26.4

14.5

3.1 1.36

1.7

1.1

0.19

0.13

0.06

0.07

0.03

N 19.13

66.0

42.3

22.5

4.96 2.05

2.8

1.7

0.2

0.16

0.06

0.07

0.03

N 19.19

105

66.0

37

-

-

-

-

0.3

0.2

0.07

-

-

N 19.26

166

106

60.8

-

-

-

-

0.4

0.25

0.09

-

-

N 21.09

DN25

166

106

60.8

11.2

1

5.58

6.8

4.3

0.3

0.2

0.09

0.1

0.06

N 21.13

264

166

92.5

17.4

1

8.68

11

7.4

0.3

0.25

0.09

0.1

0.06

N 21.18

423

264

158

30.4

1

-

17

1

10.5

1

0.3

0.3

0.1

0.15

0.9

N 21.25

660

423

251

43.4

1

-

26

1

16

1

0.48

0.58

0.1

0.17

0.13

N 41.09

DN40

423

264

158

27.9

1

13.6

17

11

0.48

0.26

0.1

0.16

0.07

N 41.13

660

423

238

43.4

1

22.3

28

1

17.4

1

0.49

0.29

0.15

0.17

0.07

N 41.19

1057

660

396

79.4

1

-

47

1

28.5

1

0.55

0.35

0.16

0.22

0.1

N 51.10

DN50

1057

660

396

74.4

1

34.7

43.4

27.9

0.62

0.36

0.17

0.22

0.1

N 51.15

1664

1057

634

118

1

55.8

68

1

43.4

1

0.68

0.44

0.19

0.23

0.1

N 51.21

2642

1664

925

192

1

-

105

1

73

1

0.8

0.61

0.2

0.29

0.15

1 only possible with guided float

INFORMATION!
The operating pressure should be at least double the pressure loss for liquids and five times for
gases. The specified pressure losses are valid for water and air at maximum flow rate.
Conversion to other products or operating data is performed by KROHNE using the calculation
method stipulated in VDI/VDE Directive 3513.

MA_GA24_R01_en_4001229901_PRT.book Page 25 Wednesday, February 2, 2011 8:57 AM