beautypg.com

Electrical connections, 3 limit switch settings – KROHNE GA 24 EN User Manual

Page 14

background image

4

ELECTRICAL CONNECTIONS

14

GA24

www.krohne.com

02/2011 - 4001229901 MA GA24 R01 en

4.3 Limit switch settings

4.3.1 Limit switch settings MS14

• Undo bracket screw 1 and set switching position
• Secure bracket screw 1

The distance between the limit switch and the casing is factory set with clamp screw 2 so that
the limit switch touches the glass taper at the maximum switching point.

The limit switch must be rotated 180° to reach the lower range of the scale.

4.3.2 Limit switch settings TG21

• Undo bracket screw 1 and set switching position
• Secure bracket screw 1

The distance between the limit switch and the casing is factory set at approx. 1 mm (0.039") with
the clamping screw 2.

MA_GA24_R01_en_4001229901_PRT.book Page 14 Wednesday, February 2, 2011 8:57 AM