TECHNICAL DATA
6
25
BATCHFLUX 5500 C
www.krohne.com
05/2014 - 4000827703 - HB BATCHFLUX 5500 R03 en
Electrical connections
Power supply
24 VDC ± 25%
Power consumption
≤ 3 W
Switch on current
≤ 5 A (< 100 μs) at 24 VDC
Voltage loss
Possible for a maximum of 20 ms according to NAMUR NE21.
BATCHMON Plus
For parameter setting and diagnostic purposes, communication via
PC with a single device (optional)
Status output
Configurable; error, flow direction, on/off
Frequency output
Frequency output
Frequency output
Frequency output
Type
Frequency (passive) / galvanically isolated from power supply
Function
All operating data preset at factory.
Interval
Counter gate time ≥ 1000 / (P
100%
[Hz])
Frequency output
≤ 10 kHz
Pulse width at full scale value
≤ 10 Hz: 50, 100, 200 or 500 ms
> 10 Hz: automatic, pulse width = 1 / (2 x f
100%
) or symmetrical, 1:1
Passive operation
Connection of electronic or electromechanical counters.
External voltage: ≤ 30 VDC / ≤ 24 VAC
Load: I
max
≤ 20 mA
Low flow cut-off
Threshold: 0...20%
Hysteresis: 0...20%
Hysteresis ≤ threshold
Depending on customers specifications.
Approvals and certifications
CE
CE
CE
CE
This device fulfills the statutory requirements of the EC directives.
The manufacturer certifies successful testing of the product by
applying the CE mark.
Electromagnetic compatibility
Directive: 2004/108/EC
Harmonized standard: EN 61326-1: 2006
Low voltage directive
Directive: 2006/95/EC
Harmonized standard: EN 61010: 20
10
Pressure equipment directive
Directive: 97/23/EC
Category SEP
Fluid group 1
Production module H
Other approvals and standards
Other approvals and standards
Other approvals and standards
Other approvals and standards
Protection category acc. to
IEC 529 / EN 60529
DN2.5...6 / DN25...40: IP 66/67
DN10...15: IP 69K
Shock test
IEC 60068-2-27
Vibration test
IEC 60068-2-64
Hygienic
DN2.5...15: 3A
FDA approved materials