beautypg.com

Technical data – KROHNE BATCHFLUX 5500 C EN User Manual

Page 24

background image

6

TECHNICAL DATA

24

BATCHFLUX 5500 C

www.krohne.com

05/2014 - 4000827703 - HB BATCHFLUX 5500 R03 en

Operating conditions

Temperature

Temperature

Temperature

Temperature

Process temperature

Dependent on ambient temperature. See chapter "Temperatures".

Cleaning temperature

SIP: Maximum 1 hour at 150°C / +302°F

CIP: Maximum 1 hour at 140°C / +284°F

Shock

≤ 3 K/s

Ambient temperature

-40…+60°C / -40…+140°F

Storage temperature

-50…+70°C / -58…+158°F

Pressure

Pressure

Pressure

Pressure

Ambient

Atmospheric

Process pressure

up to 16 bar / 232 psi for DN10...15

up to 40 bar / 580 psi for DN2.5...6 / DN25...40

Vacuum load

0 mbara / 0 psig

Chemical properties

Chemical properties

Chemical properties

Chemical properties

Physical condition

Liquids

Electrical conductivity

≥ 5 μS/cm (≥ 20 μS/cm for demineralised water)

Recommended flow velocity

-12...+12 m/s / -39...+39 ft/s

Installation conditions

Installation

For detailed information see chapter "Installation".

Inlet run

≥ 5 DN

Outlet run

≥ 2 DN

Dimensions and weights

For detailed information see chapter "Dimensions and weights".

Materials

Sensor- and converter housing

Stainless steel 1.4404 / 1.4408

Measuring tube

Fused in-place

Measuring electrodes

DN2.5...15: Cermet

DN25...40: Platinum

Process connections

Connection

Sandwich design

Optional: Pressure relief groove at flange facing of the sensor

Construction drawings of recommenced counter flanges are

available from download centre.