2.2 Operating conditions

The allowable ambient temperature and corresponding flange temperature range for the device
depends on the Ex equipment category and temperature classes marked on the nameplate.

2.2.1 Ambient and flange temperature

The equipment protection level (EPL) and temperature class give the ambient temperature and
related flange temperature ranges for the device.

EPL Ga:
Ex ia devices only - with the 4...20 mA output option

EPL Ga/Gb:
Ex ia and Ex d[ia] devices - with the 4...20 mA output option

WARNING!
The gasket temperature must be in the approved limits. For more data, refer to "Pressure and
temperature ranges" in the Installation chapter of the handbook.

INFORMATION!
The remote converter and Metaglas

®

options use the values that follow.

Temperature

class

Ambient temperature

Flange temperature

[°C]

[°F]

[°C]

[°F]

T6

-20…+57

-4…+134

-20…+60

-4…+140

Temperature

class

Ambient temperature

Flange temperature

[°C]

[°F]

[°C]

[°F]

T6

-40…+57

-40…+134

-20…+60

-4…+140

T5

-40…+72

-40…+161

-20…+60

-4…+140

T4

-40…+80

-40…+176

-20…+60

-4…+140