beautypg.com

Installation, 2 maximum surface temperature of the housing, 3 process pressure – KROHNE OPTIFLEX 1300 IECEx User Manual

Page 11

background image

INSTALLATION

2

11

OPTIFLEX 1300 C

www.krohne.com

09/2010 - 4000176402 - AD IECEX OPTIFLEX1300 R02 en

2.2.2 Maximum surface temperature of the housing

Zone 20: Ex iaD devices only
Zone 21/20: Ex iaD and Ex tD[iaD] devices only

2.2.3 Process pressure

Max. ambient temperature

Max. flange

temperature

Max. surface
temperature

Ø2 mm / Ø0.08¨

single cable probe

(HT version)

Ø2 mm / Ø0.08¨

single cable probe

(other versions)

All other probes

[°C]

[°F]

[°C]

[°F]

[°C]

[°F]

[°C]

[°F]

[°C]

[°F]

+60

+140

+60

+140

+60

+140

+60

+140

+67

+152

+75

+167

+75

+167

+75

+167

+75

+167

+82

+179

+85

+185

+85

+185

+85

+185

+85

+185

+92

+197

+75

+167

+65

+149

+70

+158

+150

+302

≤+90

≤+194

+69

+157

-

-

+60

+140

+200

+392

≤+90

≤+194

+55

+131

-

-

-

-

+300

+572

≤+90

≤+194

Equipment protection level

Allowable process pressure

[kPa]

[psi]

EPL Ga or Ga/Gb

80…110

1

11.6…16

1

Others

As per non-Ex device

As per non-Ex device

1 Atmospheric pressure