beautypg.com

General safety information, 5 iecex nameplate – KROHNE OPTIFLEX 1300 IECEx User Manual

Page 6

background image

1

GENERAL SAFETY INFORMATION

6

OPTIFLEX 1300 C

www.krohne.com

09/2010 - 4000176402 - AD IECEX OPTIFLEX1300 R02 en

1.5 IECEx nameplate

Figure 1-1: Ex ia / Ex iaD nameplate (4...20 mA output)

Figure 1-2: Ex d[ia] / Ex tD[iaD] nameplate (4...20 mA output)

1 IECEx certification agency code
2 Types of device protection for explosive atmospheres with gas, including approved Gas Groups (IIA, IIB or IIC) and tem-

perature classes (T6...T3 or T2 - depends on the probe type) and equipment protection level

3 Types of device protection for explosive atmospheres with dust, zones, degree of ingress protection (if fitted with the

appropriate cable glands) and maximum surface temperature

4 Intrinsically-safe circuit data
5 Maximum voltage in accordance with IEC 60079-0
6 Minimum waiting time after power-off before it is safe to open the terminal compartment
7 Cable entry type and size (Aluminium housing: M26×1.5, M20×1.5, ½ NPT or G ½; Stainless steel housing: M25×1.5,

M20×1.5, ½ NPT or G ½)