beautypg.com

9 supplement, 1 technical data – KROHNE OPTISOUND 3050C 4wire EN User Manual

Page 41

background image

9 Supplement

9.1 Technical data

General data
Materials, wetted parts
- Flange

PP or Alu

- swivelling holder/flange

galvanized steel

- Transducer

UP

- transducer diaphragm

Alu with PE foam rubber coating

Materials, non-wetted parts
- Housing

Alu die-casting powder-coated

- Seal ring between housing and

housing cover

silicone

- Inspection window in housing cover

for indicating/adjustment module

Polycarbonate (UL746-C listed)

- Ground terminal

316Ti/316L (1.4571/1.4435)

- transducer cable with separate ver-

sion C and D

PUR (1.1082)

Weight

2)

- compact with flange (version A)

8.0 … 13.3 kg (17.6 … 29.3 lbs)

- compact with swivelling holder

(version B)

8.7 … 10.3 kg (19.2 … 22.7 lbs)

- separate with swivelling holder

(version C)

9.2 … 11.1 kg (20.3 … 24.5 lbs)

- separate with threaded fitting

(version D)

6.5 … 7.5 kg (14.3 … 16.5 lbs)

Output variable
Output signal

4 … 20 mA/HART

Resolution

1.6 µA

Fault signal

current output unchanged; 20.5 mA; 22 mA;

<3.6 mA (adjustable)

Current limitation

22 mA

Load

max. 500 Ohm

3)

Integration time (63 % of the input

variable)

0 … 999 s, adjustable

Fulfilled NAMUR recommendation

NE 43

2)

Depending on size and process fitting material.

3)

With inductive load, ohmic share at least 25 Ohm/mH.

OPTISOUND 3050 C - 4 ... 20 mA/HART - four-wire

41

Supplement

30518

-EN

-050914