Supply voltage
24 V AC/DC (Switch mode power supply)
U
N
= 24 V DC +30% / -25%, 5W
U
N
= 24 V AC +10% / -15%, 5W
100 V AC...230 V AC + 10% / 15%, 10 V A
24 V AC/DC (Switch mode power supply)
U
N
= 24 V DC +30% / -25%, 5W
U
N
= 24 V AC +10% / -15%, 5W
100 V AC...230 V AC + 10% / 15%, 10 V A
Fuse rating
I
N
<= 1.25 A
I
N
<= 1.25 A
Outputs / inputs
Module dependant
Module dependant
Current output (IS)
Function
All operating data programmable galvanically
isolated from supply, CPU and other outputs.
Passive (Current sink, EX
i)
All operating data programmable
galvanically isolated from supply, CPU and
other outputs. Passive.
Current
4 – 20 mA
4 – 20 mA
Linearity
0.05% (reference 20 mA at 25°C)
0.05% (reference 20 mA at 25°C)
Temperature drift
<= 100 ppm/°K (Typical 30ppm/°K)
<= 100 ppm/°K (Typical 30ppm/°K)
Load
U
S
– 8V
<= 22 mA (U
S
= external supply voltage)
U
S
– 8V
<= 22 mA (U
S
= external supply voltage)
Supply
8 – 30 V
8 – 30 V
Connect ONLY to certified IS circuits with the
maximum values:
Ui = 30V, Ii = 250mA, Pi = 1W
Pulse output (IS)
Not available
Function
All operating data programmable galvanically
isolated from supply, CPU and other outputs.
Operation
Passive, loop-powered
External supply
voltage
6 – 30V DC
Current
Maximum 110 mA / 6 – 30 V DC
I high <= 900 µA (30 V)
I high <= 200 µA (8 V)
Saturation
voltage
≤
2V @ I = 110mA
Frequency
≤
1300Hz
Connect ONLY to certified IS circuits with the
maximum values:
Ui = 30V, Ii = 250mA, Pi = 1W
Status output
Not available
Function
All operating data programmable galvanically
isolated from supply, CPU and other outputs.
Operation
Passive, loop-powered
External supply
voltage
6 – 30V DC
Current
≤
110 mA
I high <= 900 µA (30 V)
I high <= 200 µA (8 V)
Connect ONLY to certified IS circuits with the
maximum values:
Ui = 30V, Ii = 250mA, Pi = 1W