KROHNE delivers the GSD with the entire device functionality, which is listed below:
Block Number
Standard-Configuration
KROHF701.GSD
Ident-No. F701
Address of the
“channel
parameter”
1
Mass Flow
AI-FB
ØxØ115
2
Density
AI-FB
ØxØ119
3
Temperature
AI-FB
ØxØ11D
4
Mass Totalizer
Totalizer-FB
ØxØ115
5
Volume Flow
AI-FB
ØxØ111
6
Percentage Mass or ° Brix
AI-FB
ØxØ139
7
Solid Flow
AI-FB
ØxØ141
8
Volume Totalizer
Totalizer-FB
ØxØ111
AI = Analog Input Function Block
FB = Function Block
Important Notes:
1. To project the PROFIBUS communication network, you have to allocate each of the
blocks to a function. On the PC-S7 from Siemens, this will be done with the Tool HW-
Config. It offers the functions which are described as follows:
2. It is possible to program an “empty block” on each block number. This means, that for this
block no data are transmitted in the cyclic data telegram.
3. There is NO Al block allowed on block position 4 and 8! Only totalizer block is here
allowed! That means the function “Analog Input (AI) is not possible. Beside the totalizer
functions is only the “empty block” allowed.
4. There is a choice between 4 different totalizer functions, which can be allocated to the
blocks 4 and/or 8. The meaning of the cyclic data transfer (Totalizer
and Status) does
always correspond the meaning in section Meaning of the Measuring- and Status
Messages. The four functions are defined as follows:
Function “Totalizer”
cyclic transfer of the totalizer
with status to the master
Function “TOT_SetTot”
cyclic transfer of the totalizer
with status to the master +
cyclic control data
from master to the device via the Bytes
SetTot
Function “TOT_Mode_Tot”
cyclic transfer of the totalizer
with status to the master +
cyclic control data
from master to the device via the Bytes
ModeTot
Function “TOT_SetTot_ModeTot”
cyclic transfer of the totalizer
with status to the master +
cyclic control data
from master to the device via the Bytes
SetTot and after that ModeTot
Both, the Byte SetTot and ModeTot are beeing sent cyclicly from Master to the device, by
inserting these bytes as output datas to the PLC configurator. The meaning of the control
bytes are as follows: