Addendum to Operating and Instruction Manual for “Modis” Converters

KROHNE Ltd

Rutherford Drive

Park Farm Industrial Estate

Wellingborough

Northamptonshire

NN8 6AE

UK

Tel. +44 1933 408 500

Fax +44 1933 408 501

WWW.KROHNE.com

Page 10 of 18

KROHF701.GSD

KROHNE delivers the GSD with the entire device functionality, which is listed below:

Block Number

Standard-Configuration

KROHF701.GSD

Ident-No. F701

Address of the

“channel

parameter”

1

Mass Flow

AI-FB

ØxØ115

2

Density

AI-FB

ØxØ119

3

Temperature

AI-FB

ØxØ11D

4

Mass Totalizer

Totalizer-FB

ØxØ115

5

Volume Flow

AI-FB

ØxØ111

6

Percentage Mass or ° Brix

AI-FB

ØxØ139

7

Solid Flow

AI-FB

ØxØ141

8

Volume Totalizer

Totalizer-FB

ØxØ111

AI = Analog Input Function Block
FB = Function Block

Important Notes:

1. To project the PROFIBUS communication network, you have to allocate each of the

blocks to a function. On the PC-S7 from Siemens, this will be done with the Tool HW-
Config. It offers the functions which are described as follows:

2. It is possible to program an “empty block” on each block number. This means, that for this

block no data are transmitted in the cyclic data telegram.

3. There is NO Al block allowed on block position 4 and 8! Only totalizer block is here

allowed! That means the function “Analog Input (AI) is not possible. Beside the totalizer
functions is only the “empty block” allowed.

4. There is a choice between 4 different totalizer functions, which can be allocated to the

blocks 4 and/or 8. The meaning of the cyclic data transfer (Totalizer

and Status) does

always correspond the meaning in section Meaning of the Measuring- and Status
Messages. The four functions are defined as follows:

Function “Totalizer”

cyclic transfer of the totalizer

with status to the master

Function “TOT_SetTot”

cyclic transfer of the totalizer

with status to the master +

cyclic control data

from master to the device via the Bytes

SetTot

Function “TOT_Mode_Tot”

cyclic transfer of the totalizer

with status to the master +

cyclic control data

from master to the device via the Bytes

ModeTot

Function “TOT_SetTot_ModeTot”

cyclic transfer of the totalizer

with status to the master +

cyclic control data

from master to the device via the Bytes

SetTot and after that ModeTot

Both, the Byte SetTot and ModeTot are beeing sent cyclicly from Master to the device, by
inserting these bytes as output datas to the PLC configurator. The meaning of the control
bytes are as follows: