6 Limits
7. Grounding
•
Warning: All flowmeters must be properly grounded to avoid personnel shock hazard.
•
The ground conductor should not transmit any interference voltages, therefore do not ground
any other electrical devices together with this conductor.
Separate primary head IFS 6000 F with terminal box
•
A functional ground FE must always be connected.
•
Signal converters with a field power supply of > 125 mA / > 60 V:
Because of the higher field current from the signal converter, a PE protective conductor must
be connected to the IFS 6000 F primary head, see grounding diagrams.
Connections
Connection
meter size
Max. operating pressure in bar/psig at product temperature of ...
Flange DIN 2501/PN 40
Flange JIS 2210/20 K
Flange ANSI B 16.5: 150 lb
300 lb
Aseptic weld-on connection
for pipes to DIN 11 850
Aseptic weld-on connection
for pipes to ISO 2037
Dairy screw connection DIN 11 851
Screwed pipe connection ISO 2853
Screwed pipe connection SMS 1145
Clamp joint ISO 2852
DN 10*-15
DN 10*-15
1
/
2
”*
1
/
2
”*
DN 10*-40
DN 50-80
12*-38/1”-1
1
/
2
”
51-76.1/2”-3”
DN 10*-40
DN 50-80
12*-38 mm
51-76.1 mm/1
1
/
2
”-3.0”
25-76 mm
12*-51 mm/1
1
/
2
”-2.0”
63.5-76.1 mm/2
1
/
2
”-3.0”
< 40°C
(< 105°F)
39
.6
(566)
39
.6
(566)
19.6 (284)
39
.6
(566)
40
.6
(580)
25
.6
(360)
40
.6
(580)
25
.6
(360)
40
.6
(580)
25
.6
(360)
40
.6
(580)
25
.6
(360)
0
6
.6 0
(90)
16
.6
(230)
10
.6
(150)
< 60°C
(< 140°F)
37
.6
(537)
37
.6
(537)
19.0 (276)
37
.6
(537)
40
.6
(580)
25
.6
(360)
40
.6
(580)
25
.6
(360)
40
.6
(580)
25
.6
(360)
40
.6
(580)
25
.6
(360)
0
6
.6 0
(90)
16
.6
(230)
10
.6
(150)
< 70°C
(< 158°F)
36
.6
(522)
36
.6
(522)
18.7 (271)
36
.6
(522)
40
.6
(580)
25
.6
(360)
40
.6
(580)
25
.6
(360)
40
.6
(580)
25
.6
(360)
40
.6
(580)
25
.6
(360)
0
6
.6 0
(90)
16
.6
(230)
10
.6
(150)
< 90°C
(< 195°F)
34
.6
(493)
34
.6
(493)
18.1 (263)
34
.6
(493)
40
.6
(580)
25
.6
(360)
40
.6
(580)
25
.6
(360)
40
.6
(580)
25
.6
(360)
40
.6
(580)
25
.6
(360)
0
6
.6 0
(90)
16
.6
(230)
10
.6
(150)
< 100°C
(< 210°F)
33
.6
(479)
33
.6
(479)
17.7 (257)
33
.6
(479)
40
.6
(580)
25
.6
(360)
40
.6
(580)
25
.6
(360)
40
.6
(580)
25
.6
(360)
40
.6
(580)
25
.6
(360)
0
6
.6 0
(90)
16
.6
(230)
10
.6
(150)
< 120°C
(< 250°F)
32
.6
(464)
32
.6
(464)
17.0 (247)
32
.6
(464)
40
.6
(580)
25
.6
(360)
40
.6
(580)
25
.6
(360)
40
.6
(580)
25
.6
(360)
40
.6
(580)
25
.6
(360)
0
6
.6 0
(90)
16
.6
(230)
10
.6
(150)
< 140°C **
(< 285°F)
30
.6
(435)
30
.6
(435)
16.2 (235)
30
.6
(435)
40
.6
(580)
25
.6
(360)
40
.6
(580)
25
.6
(360)
40
.6
(580)
25
.6
(360)
40
.6
(580)
25
.6
(360)
–
–
–
Vacuum load all sizes
0 mbar abs.
< 180°C **
(< 355°F)
28
.6
(406)
28
.6
(406)
14.7 (213)
28
.6
(406)
–
–
–
–
–
–
–
–
–
–
–
*
*
size DN 2.5 - 10 /
1
/
10
” -
3
/
8
”
** max. process temperature 140°C (285°F) for compact flowmeters
ambient temperature here max. 40°C/104°F.