Installation in the pipeline

L

max

L

min

Installation material, see page 3.

Pipe and operating pressures,
see Section 6 “Limits”.

Flange spacing
= dimension “a” + 2 x gasket thickness of D2
(dimension “a”: see Sect. 11 “Dimensions and weights”;
arrangement of gaskets: see Sect. 7 “Grounding”).

High-temperature pipelines
Where process temperatures exceed 100 °C/212 °F, provide for facilities to
compensate for longitudinal expansion on heat-up of the pipeline.
For short pipelines use resilient gaskets and
for long pipelines install flexible pipe elements (e.g. elbows).

Position of flanges

• Torques

Install flowmeter in line with the pipe

For all flanged instruments to DIN, ANSI

axis. Pipe flange faces must be

and JIS

parallel to each other,

Tighten down stud bolts and nuts uniformly

max. permissible deviation:

in the sequence (1-8) shown in the drawing.

L

max

- L

min

≤≤

0.5 mm

Max. torque:

0.02”

32 Nm ~ 3.2 kpm ~ 23.1 ft x lbf

For all other connections to DIN and ISO
Tighten down to metal stop.