beautypg.com

Device description, 6 ambient temperature / temperature classes – KROHNE OPTIBAR PM 5060 C Ex ia EN User Manual

Page 9

background image

DEVICE DESCRIPTION

2

9

OPTIBAR 5060

www.krohne.com

04/2014 - 4003591801 - AD OPTIBAR 5060 Ex ia R01 en

2.6 Ambient temperature / temperature classes

OPTIBAR * 5060 VGK5/6/D*A/W C/U/0/H/T with integrated electronics Z (4

OPTIBAR * 5060 VGK5/6/D*A/W C/U/0/H/T with integrated electronics Z (4

OPTIBAR * 5060 VGK5/6/D*A/W C/U/0/H/T with integrated electronics Z (4

OPTIBAR * 5060 VGK5/6/D*A/W C/U/0/H/T with integrated electronics Z (420 mA),

20 mA),

20 mA),

20 mA),

H (4

H (4

H (4

H (420 mA/HART) or A (4

20 mA/HART) or A (4

20 mA/HART) or A (4

20 mA/HART) or A (420 mA/HART with SIL qualification), version with single chamber

20 mA/HART with SIL qualification), version with single chamber

20 mA/HART with SIL qualification), version with single chamber

20 mA/HART with SIL qualification), version with single chamber

housing A, K V or 8

housing A, K V or 8

housing A, K V or 8

housing A, K V or 8

The max. permissible ambient temperatures depending on the temperature classes are
specified in the following tables.

Category 1G equipment

Category 1G equipment

Category 1G equipment

Category 1G equipment

For applications requiring equipment category 1G, the process pressure of the media must be
between 0.8…1.1 bar. With the stated permissible ambient temperatures, the 80% consideration
of section 6.4.2/EN 1127-1 is taken into account. The application conditions in areas without
hazardous mixtures are specified in the manufacturer information.

Category 1/2G equipment

Category 1/2G equipment

Category 1/2G equipment

Category 1/2G equipment

For applications requiring equipment category 1/2G, the process pressure of the media must be
between 0.8…1.1 bar. With the stated permissible ambient temperatures, the 80% consideration
of section 6.4.2/EN 1127-1 is taken into account. If OPTIBAR * 5060 VGK5/6/D*A/W C/U/0/H/T are
operated at temperatures higher than those specified in the table above, please make sure by
means of appropriate measures that there is no danger of ignition from the hot surface. The
maximum temperature on the electronics/housing should not exceed the values stated in the
table above. The application conditions in areas without hazardous mixtures are specified in the
manufacturer information.

Temperature class

Ambient temperature range at the electronics and media
temperature range at the sensor

T6

-20...+23°C / -4...+73.4°F

T5, T4, T3, T2, T1

-20...+60°C / -4...+140°F

Temperature class

Ambient temperature range at
the electronics (zone 1)

Media temperature range at the
sensor (zone 0)

T6

-50...+39°C / -58...+102.2°F

-20...+23°C / -4...+73.4°F

T5, T4, T3, T2, T1

-50...+70°C / -58...+158°F

-20...+60°C / -4...+140°F

.book Page 9 Thursday, June 5, 2014 3:05 PM