KROHNE OPTIBAR PM 5060 C Ex ia EN User Manual
Page 18
4
FURTHER NOTES
18
OPTIBAR 5060
www.krohne.com
04/2014 - 4003591801 - AD OPTIBAR 5060 Ex ia R01 en
4.6 Installation / mounting
The OPTIBAR * 5060 VGK5/6/D*A/W C/U/0/H/T must be mounted such that the sensor is
effectively secured against touching the vessel wall, under consideration of other vessel
installations and flow conditions in the vessel. This applies especially to suspension pressure
transmitters and versions with distance tube lengths over 3 m.
4.7 Mounting of the OPTIBAR * 5060 VGK5/6/D*A/W C/U/0/H/T with remote
housing
With the version with remote housing of the pressure transmitter
OPTIBAR * 5060 VGK5/6/D*A/W C/U/0/H/T the equipotential bonding must be provided in the
complete mounting area of the connection cable between electronics housing and transmitter
housing.
.book Page 18 Thursday, June 5, 2014 3:05 PM