4.6 Installation / mounting

The OPTIBAR * 5060 VGK5/6/D*A/W C/U/0/H/T must be mounted such that the sensor is
effectively secured against touching the vessel wall, under consideration of other vessel
installations and flow conditions in the vessel. This applies especially to suspension pressure
transmitters and versions with distance tube lengths over 3 m.

4.7 Mounting of the OPTIBAR * 5060 VGK5/6/D*A/W C/U/0/H/T with remote

housing

With the version with remote housing of the pressure transmitter
OPTIBAR * 5060 VGK5/6/D*A/W C/U/0/H/T the equipotential bonding must be provided in the
complete mounting area of the connection cable between electronics housing and transmitter
housing.