Device description, 8 electrical data – KROHNE OPTITEMP TC 100 Ex EN User Manual
Page 8
2
DEVICE DESCRIPTION
8
OPTITEMP TR/TC100
www.krohne.com
08/2010 - 4001022701 - Ex AD OPTITEMP TR/TC 100 R01
Regardless of the temperature class, the lower limit value for the product temperature for all
versions is:
• TC 100: T
M
= -40°C / -40°F
• TR 100: T
M
= -200°C / -328°F
2.8 Electrical data
Connect the sensor circuit of a measuring insert only to intrinsically safe circuits as well as
separate transmitters certified as intrinsically safe or zener barriers. Observe the following
maximum values:
• U
i
= 30 V
• I
i
= 140 mA
• P
i
= 1.0 W
Keep in mind the following maximum values for effective capacities and inductances when
interconnecting:
Sensor length
up to 5 m / 16.4 ft
up to 30 m / 98.4 ft
C
i
= [nF]
L
i
= [µH]
C
i
= [nF]
L
i
= [µH]
TR100 with Pt100 wire wound
3.5
65
21
390
TC100 type K
2.5
25
14
150
TC100 type J
2
48.5
11.5
289.5
.book Page 8 Wednesday, August 11, 2010 11:40 AM