Regardless of the temperature class, the lower limit value for the product temperature for all
versions is:

• TC 100: T

M

= -40°C / -40°F

• TR 100: T

M

= -200°C / -328°F

2.8 Electrical data

Connect the sensor circuit of a measuring insert only to intrinsically safe circuits as well as
separate transmitters certified as intrinsically safe or zener barriers. Observe the following
maximum values:

• U

i

= 30 V

• I

i

= 140 mA

• P

i

= 1.0 W

Keep in mind the following maximum values for effective capacities and inductances when
interconnecting:

Sensor length

up to 5 m / 16.4 ft

up to 30 m / 98.4 ft

C

i

= [nF]

L

i

= [µH]

C

i

= [nF]

L

i

= [µH]

TR100 with Pt100 wire wound

3.5

65

21

390

TC100 type K

2.5

25

14

150

TC100 type J

2

48.5

11.5

289.5