2

DEVICE DESCRIPTION

6

OPTITEMP TR/TC100

www.krohne.com

08/2010 - 4001022701 - Ex AD OPTITEMP TR/TC 100 R01

2.5 Equipment category

The measuring inserts are designed in category II 1 G for use in Zone 0.

For detailed information refer to

Flammable products on page 5.

2.6 Protection types

The marking according to ATEX is: II 1G Ex ia IIC T6

II 1G Ex ia IIC T6

II 1G Ex ia IIC T6

II 1G Ex ia IIC T6

The following types of protection are used:

• The measuring insert is designed in protection type intrinsically safe "i".
• Operation on intrinsically safe circuits with protection level "ia".

INFORMATION!
Definition of Zone 0 according to EN 1127-1:
An area with a constant or long-term or frequent explosive atmosphere made up of a mixture of
flammable substances in the form of gas, vapours or mist.

.book Page 6 Wednesday, August 11, 2010 11:40 AM