Service, Service 6.1 maintenance, 2 dismantling – KROHNE OPTITEMP TC 100 Ex EN User Manual
Page 14
6
SERVICE
14
OPTITEMP TR/TC100
www.krohne.com
08/2010 - 4001022701 - Ex AD OPTITEMP TR/TC 100 R01
Service
6.1 Maintenance
For systems in hazardous areas, regular tests are required in order to maintain the proper
condition. The manufacturer recommends checking the following components regularly for
corrosion and damage:
• Housing
• Cable entry(ies)
• Feed lines
6.2 Dismantling
DANGER!
Maintenance measures of a safety-relevant nature within the meaning of explosion protection
may only be carried out by the manufacturer, his authorised representative or under the
supervision of authorised inspectors.
DANGER!
To avoid injury and material damage caused by electric shock, only remove the measuring insert
in a de-energised state!
CAUTION!
So as not to damage the cover of the connection head, only open it using a suitable tool (e.g. a
screwdriver).
INFORMATION!
You can replace the measuring insert with a measuring insert identical in construction.
.book Page 14 Wednesday, August 11, 2010 11:40 AM