Technical data – KROHNE BM 26 BASIC_ADVANCED Quickstart EN User Manual
Page 26
4
TECHNICAL DATA
26
BM 26 BASIC/ADVANCED
www.krohne.com
10/2012 - 4000346904 - QS BM 26 Basic-Adv R04 en
Electrical connections
Power supply
Power supply
Power supply
Power supply
Voltage
Non-Ex:
Non-Ex:
Non-Ex:
Non-Ex:
9...32 VDC
Ex ia:
Ex ia:
Ex ia:
Ex ia:
Refer to supplementary instructions or approval certificates
Cable entry
M20 × 1.5
Intrinsically-safe circuit data for
Ex ia-approved devices
Refer to supplementary instructions or approval certificates
PROFIBUS PA
PROFIBUS PA
PROFIBUS PA
PROFIBUS PA
Description
-
PROFIBUS PA protocol Profile
A&B, ver.3.0 (EN 50170 vol.2)
FOUNDATION Fieldbus
FOUNDATION Fieldbus
FOUNDATION Fieldbus
FOUNDATION Fieldbus
Description
FOUNDATION Fieldbus protocol
-
Approvals and certification
CE
This device fufills the statutory requirements of the EC directives.
The manufacturer certifies successful testing of the product by
applying the CE mark.
Explosion protection
Explosion protection
Explosion protection
Explosion protection
ATEX
II 1 G Ex ia IIC T4...T6
2
II 1 G Ex ia IIC T4...T6
2
II 2 G Ex ib IIC T4...T6
3
II 2 G Ex ib IIC T4...T6
3
Other standards and approvals
Other standards and approvals
Other standards and approvals
Other standards and approvals
EMC
Electromagnetic Compatibility Directive 2004/108/EC in conjunction
with EN 61326-1 (2006)
Vibration resistance
Vibration class 4M4 according to EN 60721-3-4
1 The customer must specify the position of the converter at the top or the bottom of the analog transmitter
2 Conventional or FISCO systems intrinsically-safe systems
3 FISCO systems intrinsically-safe systems
Module output
FOUNDATION™ Fieldbus
PROFIBUS PA
Order code
xF45xDxxxxx (PR)
xF45xXxxxxx (PR)