ELECTRICAL CONNECTIONS

3

17

BM 26 BASIC/ADVANCED

www.krohne.com

10/2012 - 4000346904 - QS BM 26 Basic-Adv R04 en

3.3 Protection category

For the IP categories of the accessories for the device, refer to the table that follows:

Protection categories according to EN 60529

How to make sure that the electrical installation agrees with the protection category

• Make sure that the gaskets are not damaged.
• Make sure that the electrical cables are not damaged.
• Make sure that the electrical cables agree with the national electrical code.
• The cables are in a loop in front of the device 1 so water cannot enter the housing.
• Tighten the cable glands 2.
• Close unused cable glands with dummy plugs 3.

Equipment housing

IP category

Analog transmitter

Non-Ex / Ex i (without indicator)

54

Non-Ex / Ex i (with indicator)

66

Limit switches

Non-Ex / Ex i

66

DANGER!
Make sure the cable gland is watertight.

Figure 3-6: Protection category