TECHNICAL DATA

24

BM 26 BASIC/ADVANCED

www.krohne.com

10/2012 - 4000346904 - QS BM 26 Basic-Adv R04 en

LCD indicator; voltage drop

2.5 V

2.5 V

Cable entry

M20 × 1.5

Intrinsically-safe circuit data for

Ex ia-approved devices

Refer to supplementary instructions or approval certificates

Input and output

Current output

Current output

Current output

Current output

Output range

4…20 mA

Error signal

Upper value, selectable

21.6 mA

23 mA

Lower value, selectable

3.5 mA

HART

HART

HART

HART®

Description

-

HART® protocol via passive

current output

Multidrop operation

-

Yes, current output = 4 mA

Multidrop address (1...15)

adjustable

Approvals and certifications

CE

This device fulfils the statutory requirements of the EC directives.

The manufacturer certifies successful testing of the product by

applying the CE mark.

Explosion protection

Explosion protection

Explosion protection

Explosion protection

ATEX - without LCD indicator

II 1 G Ex ia IIC T4...T6

II 1 G Ex ia IIC T4 or T6

ATEX - with LCD indicator

II 1 G Ex ia IIC T5

-

Other standards and approvals

Other standards and approvals

Other standards and approvals

Other standards and approvals

EMC

Electromagnetic Compatibility

Directive 2004/108/EC in

conjunction with EN 61326-1

(2006)

Electromagnetic Compatibility

Directive 2004/108/EC in

conjunction with EN 61326-1

(2006)

NAMUR NE 21

3

Vibration resistance

Vibration class 4M4 according to EN 60721-3-4

NAMUR

NAMUR NE 43

4

1 If the operating temperature is not in these limits, the display switches off. The transmitter module continues to oper-

ate above and below this temperature range.

2 This value is programmable
3 Electromagnetic Compatibility of Industrial and Laboratory Control Equipment
4 Standardization of the Signal Level for the Failure Information of Digital Transmitters

Module output

4...20 mA

4...20 mA / HART®

Order code

xF45xBxxxxx (without

LCD indicator)

xF45xExxxxx

(with LCD indicator)

xF45xWxxxxx

(without LCD indicator)

xF45xGxxxxx

(with LCD indicator)