Installation, 7 how to turn or remove the signal converter – KROHNE OPTIWAVE 5200 C_F Quickstart EN User Manual
Page 19
INSTALLATION
2
19
OPTIWAVE 5200 C/F
www.krohne.com
08/2013 - 4001905202 - QS OPTIWAVE 5200 R02 en
antenna extension, "S" antenna extension or "L" (right angle) antenna extension.
Procedure 2A: Device settings for a device with a straight antenna extension
• Enter the SUPERVISOR menu (2.0.0).
• Push [>>>>], 2 × [
], [>>>>] and 6 × [
] to go to menu item ANTENNA EXTENSION (2.3.7).
• Push [>>>>] to change the value. Push [>>>>] to change the position of the cursor. Push [
] to
decrease the value or [
] to increase the value.
i
If the antenna extension has a length of 500 mm, enter the value "500" (if units for this
menu item are in mm).
• Push 3 × [^
^
^
^] to go back to the "STORE" screen.
• Push [
] or [
] to set the screen to STORE YES
STORE YES
STORE YES
STORE YES and push [^
^
^
^].
i
End of the procedure.
Procedure 2A: Device settings for a device with an "S" or L" (right angle) antenna
extension
• Enter the SUPERVISOR menu (2.0.0).
• Push [>>>>], 2 × [
], [>>>>] and 6 × [
] to go to menu item ANTENNA EXTENSION (2.3.7).
• Push [>>>>] to change the value. Push [>>>>] to change the position of the cursor. Push [
] to
decrease the value or [
] to increase the value.
i
If units are in mm, enter the value "243" (for an "S" extension) or "236" (for an "L"
extension).
• Push [^
^
^
^] to go back to the menu. Push 2 × [
] to go to menu item DIST.PIECE (2.3.9).
• Push [>>>>] to change the value. Push [>>>>] to change the position of the cursor. Push [
] to
decrease the value or [
] to increase the value.
i
If units are in mm, enter the value "221" (for an "S" extension) or "236" (for an "L"
extension).
• Push 3 × [^
^
^
^] to go back to the "STORE" screen.
• Push [
] or [
] to set the screen to STORE YES
STORE YES
STORE YES
STORE YES and push [^
^
^
^].
i
End of the procedure.
Settings for devices with antenna extensions in mm
2.7.7 How to turn or remove the signal converter
The converter turns 360°, but we recommend that the tag hole on the housing points to the
nearest tank wall. For more data, refer to
Recommended mounting position
on page 9. The
converter can be removed from the process connection assembly under process conditions.
Antenna extension type
Device settings
ANTENNA EXTENSION (2.3.7)
DIST.PIECE (2.3.9)
Straight
1
0
2
"S"
243
221
2
"L" (right angle)
236
236
2
1 This value depends on the length of the antenna extension. Enter the length of the antenna extension: 100, 200, 300,
400, 500 or 1000 mm
2 If the device has a high temperature extension, add 120 mm to this value