4.2 Connecting the external battery

4.2.1 IP67 housing (compact and field version)

• Remove the protection cap and loosen the 4 Allen bolts (4mm).
• Remove the cover.
• Remove one of the blind cable glands in the bottom of the converter housing.
• Remove the metal strip at the bottom of the housing (2 screws).
• Lead the cable of the external battery through the gland opening and mount the attached cable

gland loosely.

• Pull the cable to the top of the electronics.
• Fasten the battery connector to the internal connector in the converter.
• Check if the display lights up.
• Refit the metal strip at the bottom of the housing.
• Tighten the cable gland.
• Put back the cover.

• Tighten the 4 bolts and put back the protection cap (IP67 housing).
• For closing the case of the converter in the IP68 housing, please refer to

IP68 housing,

compact version

on page 20.

4.2.2 IP68 housing (compact version)

The output cable has two color coded leads for connecting the external battery. For detailed
information, please refer to

IP68 housing (compact version)

on page 25.

WARNING!
Make sure that the battery cable is not jammed by the cover.

INFORMATION!
The instrument now operates with default menu settings.