beautypg.com

Installation, 8 installation conditions – KROHNE WATERFLUX 3070 Quickstart EN User Manual

Page 11

background image

INSTALLATION

2

11

WATERFLUX 3070

www.krohne.com

06/2013 - 4002400602 - QS WATERFLUX 3070 R05 en

2.8 Installation conditions

2.8.1 Inlet and outlet

2.8.2 T-section

DN25...300

Figure 2-7: Minimal inlet and outlet

1 Inlet: ≥ 0 DN
2 Outlet: ≥ 0 DN

DN350...600

Figure 2-8: Minimal inlet and outlet

1 Inlet: ≥ 3 DN
2 Outlet: ≥ 1 DN

Figure 2-9: Distance behind a T-section

1 DN 25...300: ≥ 0 DN & DN 350...600: ≥ 3 DN